Optimizacija "in house" reagensa za imunohematološka ispitivanja na sustavu Beckman Coulter PK 7300


Hecimovic, Ana; Stojić Vidović, Miljana; Juraković Lončar Nina; Balija, Melita
Optimizacija "in house" reagensa za imunohematološka ispitivanja na sustavu Beckman Coulter PK 7300 // Vox Sanguinis / Devive, D. (ur.).
London, Ujedinjeno Kraljevstvo: Wiley-Blackwell, 2015. str. 258-259 (poster, međunarodna recenzija, pp prezentacija, znanstveni)


CROSBI ID: 848482 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Optimizacija "in house" reagensa za imunohematološka ispitivanja na sustavu Beckman Coulter PK 7300
(Optiomization of ih house reagents for immunohematology testing on Beckman Coulter PK 7300 System)

Autori
Hecimovic, Ana ; Stojić Vidović, Miljana ; Juraković Lončar Nina ; Balija, Melita

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, pp prezentacija, znanstveni

Izvornik
Vox Sanguinis / Devive, D. - : Wiley-Blackwell, 2015, 258-259

Skup
25th Regional Congress of the International Society of Blood Transfusion

Mjesto i datum
London, Ujedinjeno Kraljevstvo, 27.06.2015. - 01.07.2015

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
in vitro dijagnostici vlastitte proizvodnje
(in house reagents)

Sažetak
Since 1996 CITM is a manufacturer of "in house" monoclonal reagents which are prepared from blood typing intermediates for further manufacturing use by Merck Millipore. The assortment includes reagents for ABO, RhD, Rh phenotype and Kell antigen blood grouping and very soon it will includes reagents for M, S, Jka, Jkb antigen typing also. It is essential that blood grouping reagents are prepared using reliable manufacturing procedures that are consistently capable of producing safe and efficacious products. The products must comply with requirements of the EU Directive (98/79/EC) on in vitro diagnostic (IVD) medical devices and other relevant international standards. These types of reagents according to the classification of Directive 98/79 / EC Annex II fall under List A, or in the IVD of high risk to the health of the individual. Therefore, all processes are running within the quality system ISO 9001:2008 and ISO 13485:2003, which is in the process of setting. Aim: Present the results of validation which is a part of the adjustment process of “in house” reagents on PK7300BC system. The validation was carried out according to the instructions amending Decision 2002/364 / EC on common technical specifications for in vitro diagnostic medical devices (2009/886 / EC) and the Guidelines for the blood transfusion services. Methods: By dilution, blending and chemical additions “in house” blood grouping regents are formulated for a variety of techniques including microaglutination technique for automatic system PK7300BC. Bromelain solution was prepared in 0, 1% concentration. 3129 ABO and RH1 (D) tests (2% "weak D") and 3199 Kell antigens and Rh phenotype (C, c, E, e) tests was carried out in parallel with the "in house" reagents and CE mark commercial reagents (Sifin), according to the CITM algorithm for testing blood donors. Routine work was simulated during validation. Discrepant results were confirmed by gel microcolumn assay (Bio-Rad) and by tube technique (Ortho-Clinical Diagnostics). Results 1. The accuracy of the interpreted results of ABO and RH1 (D) blood group system and Kell antigen was 100%. 2. The accuracy of Rh phenotype was 99.95% ; four discrepancies of C antigen are probably due to a technical problem, well contamination. In the next donations, results of C typing were correct. 3. A weak types of D antigen: 1, 2, 3 and 14, are interpreted as D positive. Conclusion: Results of validation are more than satisfactory, especially if we consider the reasons for discrepant results for the C antigen using “in house” reagents. Interpretation of weak D types as RhD positive will reduce further testing of blood donors. The application of the "in house" blood grouping reagents on Beckman Coulter PK 7300 automated system for testing DDK proved to be very reliable.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti



POVEZANOST RADA


Ustanove:
Hrvatski zavod za transfuzijsku medicinu

Profili:

Avatar Url Ana Hećimović (autor)

Avatar Url Melita Balija (autor)


Citiraj ovu publikaciju:

Hecimovic, Ana; Stojić Vidović, Miljana; Juraković Lončar Nina; Balija, Melita
Optimizacija "in house" reagensa za imunohematološka ispitivanja na sustavu Beckman Coulter PK 7300 // Vox Sanguinis / Devive, D. (ur.).
London, Ujedinjeno Kraljevstvo: Wiley-Blackwell, 2015. str. 258-259 (poster, međunarodna recenzija, pp prezentacija, znanstveni)
Hecimovic, A., Stojić Vidović, M., Juraković Lončar Nina & Balija, M. (2015) Optimizacija "in house" reagensa za imunohematološka ispitivanja na sustavu Beckman Coulter PK 7300. U: Devive, D. (ur.)Vox Sanguinis.
@article{article, author = {Hecimovic, Ana and Stoji\'{c} Vidovi\'{c}, Miljana and Balija, Melita}, editor = {Devive, D.}, year = {2015}, pages = {258-259}, keywords = {in vitro dijagnostici vlastitte proizvodnje}, title = {Optimizacija "in house" reagensa za imunohematolo\v{s}ka ispitivanja na sustavu Beckman Coulter PK 7300}, keyword = {in vitro dijagnostici vlastitte proizvodnje}, publisher = {Wiley-Blackwell}, publisherplace = {London, Ujedinjeno Kraljevstvo} }
@article{article, author = {Hecimovic, Ana and Stoji\'{c} Vidovi\'{c}, Miljana and Balija, Melita}, editor = {Devive, D.}, year = {2015}, pages = {258-259}, keywords = {in house reagents}, title = {Optiomization of ih house reagents for immunohematology testing on Beckman Coulter PK 7300 System}, keyword = {in house reagents}, publisher = {Wiley-Blackwell}, publisherplace = {London, Ujedinjeno Kraljevstvo} }




Contrast
Increase Font
Decrease Font
Dyslexic Font