Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 847299

Comparison of simulation results obtained by calibrated and non-calibrated VISSIM


Ištoka Otković, Irena
Comparison of simulation results obtained by calibrated and non-calibrated VISSIM // PTV User Group Meeting
Zagreb, Hrvatska, 2016. (pozvano predavanje, nije recenziran, neobjavljeni rad, ostalo)


CROSBI ID: 847299 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparison of simulation results obtained by calibrated and non-calibrated VISSIM

Autori
Ištoka Otković, Irena

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, neobjavljeni rad, ostalo

Skup
PTV User Group Meeting

Mjesto i datum
Zagreb, Hrvatska, 06.10.2016. - 07.10.2016

Vrsta sudjelovanja
Pozvano predavanje

Vrsta recenzije
Nije recenziran

Ključne riječi
traffic micro-simulation model; VISSIM; calibration; validation

Sažetak
The micro-simulation model VISSIM are unquestionably a very useful tool, but it is questionable whether they can be expected to give realistic modeling results that can be applied within the methodology, analysis and design of traffic infrastructure in local conditions. I'd like to introduce a new method of calibration that we have developed and which is based on the application of neural network. The comparison of the simulated and measured traffic indicators, in real traffic conditions, provides the best insight into the success of the model calibration process. The traffic indicator, used for the calibration of the model, is the travel time between the measuring points at a chosen urban intersection. The calibrated model has predicted the travel time for new sets of measured data at the same intersection and second intersection with the prediction error smaller than 5%.A higher standard of validation is reached, if it can be confirmed that the model calibrated with one type of data can also give good estimates of other types of traffic data, such as queue parameters. VISSIM can provide realistic modeling results when the calibration of the model is done.

Izvorni jezik
Engleski

Znanstvena područja
Građevinarstvo, Tehnologija prometa i transport



POVEZANOST RADA


Ustanove:
Građevinski i arhitektonski fakultet Osijek

Profili:

Avatar Url Irena Ištoka Otković (autor)


Citiraj ovu publikaciju:

Ištoka Otković, Irena
Comparison of simulation results obtained by calibrated and non-calibrated VISSIM // PTV User Group Meeting
Zagreb, Hrvatska, 2016. (pozvano predavanje, nije recenziran, neobjavljeni rad, ostalo)
Ištoka Otković, I. (2016) Comparison of simulation results obtained by calibrated and non-calibrated VISSIM. U: PTV User Group Meeting.
@article{article, author = {I\v{s}toka Otkovi\'{c}, Irena}, year = {2016}, keywords = {traffic micro-simulation model, VISSIM, calibration, validation}, title = {Comparison of simulation results obtained by calibrated and non-calibrated VISSIM}, keyword = {traffic micro-simulation model, VISSIM, calibration, validation}, publisherplace = {Zagreb, Hrvatska} }
@article{article, author = {I\v{s}toka Otkovi\'{c}, Irena}, year = {2016}, keywords = {traffic micro-simulation model, VISSIM, calibration, validation}, title = {Comparison of simulation results obtained by calibrated and non-calibrated VISSIM}, keyword = {traffic micro-simulation model, VISSIM, calibration, validation}, publisherplace = {Zagreb, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font