Pregled bibliografske jedinice broj: 8463
Corrosion Inhibition of the Low Alloyed CrMo Steel
Corrosion Inhibition of the Low Alloyed CrMo Steel // EUROCORR96, Session II corrosion Inhibitors, Extended Abstracts / G.Trabanelli (ur.).
Nica, Francuska: Centre Français de L anticorrosion Societe de Chimie Industriell, 1996. str. IIP18 1 - 5 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 8463 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Corrosion Inhibition of the Low Alloyed CrMo Steel
Autori
Gojić, Mirko ; Horvat, Roberta ; Metikoš-Huković, Mirjana
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
EUROCORR96, Session II corrosion Inhibitors, Extended Abstracts
/ G.Trabanelli - : Centre Français de L anticorrosion Societe de Chimie Industriell, 1996, IIP18 1 - 5
Skup
EUROCORR96
Mjesto i datum
Nica, Francuska, 24.09.1996. - 26.09.1996
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
low alloyed CrMo steel; corrosion inhibition; adsorption; propargylic alcohol; impedance spectrosopy; voltammetry
Sažetak
Corrosion problems in the oil and petrochemical industry have usually been solved by selection of suitable materials and/or by changing the environment to make it less aggressive. In this work the protective action of propargylic alcohol (PA), as corrosion inhibitor of the low alloy CrMo steel dissolution in 0.5 M H_2SO_4 solution, was studied by DC-polarization and AC-impedance spectroscopy measurements.
According to the results of polarization measurements, propargylic alcohol could be treated as a mixed type inhibitor. Impedance spectroscopy showed that the inhibitor adsorption was specific, decreased surface heterogeneity and caused formation of the protective surface film.
The inhibition process was treated as the substitutional adsorption process. Standard free energy of adsorption calculated on the basis of DC-polarization and AC-impedance measurements at the open circuit potential E_oc, using Flory-Huggins isotherm, was -15 kJmol^-1. The number of replaced water molecules, obtained after planar orientation of adsorbed PA molecule, was 3.
Izvorni jezik
Engleski
Znanstvena područja
Kemija