Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 844005

Accurate cloud-based smart IMT measurement, its validation and stroke risk stratification in carotid ultrasound: A web-based point-of-care tool for multicenter clinical trial


Saba, Luca; Sumit, Banchhor; Suri, Harman; Londhe, Narendra; Araki, Tadashi; Ikeda, Nobutaka; Višković, Klaudija; Shafique, Shoaib; Laird, John; Gupta, Ajay et al.
Accurate cloud-based smart IMT measurement, its validation and stroke risk stratification in carotid ultrasound: A web-based point-of-care tool for multicenter clinical trial // Computers in biology and medicine, 75 (2016), 217-234 doi:10.1016/j.compbiomed.2016.06.010 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 844005 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Accurate cloud-based smart IMT measurement, its validation and stroke risk stratification in carotid ultrasound: A web-based point-of-care tool for multicenter clinical trial

Autori
Saba, Luca ; Sumit, Banchhor ; Suri, Harman ; Londhe, Narendra ; Araki, Tadashi ; Ikeda, Nobutaka ; Višković, Klaudija ; Shafique, Shoaib ; Laird, John ; Gupta, Ajay ; Nicolaides, Andrew ; Suri, Jajsit

Izvornik
Computers in biology and medicine (0010-4825) 75 (2016); 217-234

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Stroke ; Carotid ; Atherosclerosis ; Ultrasound ; Telemedicine ; Cloud ; cIMT ; Routine

Sažetak
This study presents AtheroCloud™ - a novel cloud- based smart carotid intima-media thickness (cIMT) measurement tool using B-mode ultrasound for stroke/cardiovascular risk assessment and its stratification. This is an anytime–anywhere clinical tool for routine screening and multi- center clinical trials. In this pilot study, the physician can upload ultrasound scans in one of the following formats (DICOM, JPEG, BMP, PNG, GIF or TIFF) directly into the proprietary cloud of AtheroPoint from the local server of the physician’s office. They can then run the intelligent and automated AtheroCloud™ cIMT measurements in point-of-care settings in less than five seconds per image, while saving the vascular reports in the cloud. We statistically benchmark AtheroCloud™ cIMT readings against sonographer (a registered vascular technologist) readings and manual measurements derived from the tracings of the radiologist. One hundred patients (75 M/25 F, mean age: 68711 years), IRB approved, Toho University, Japan, consisted of Left/Right common carotid artery (CCA) artery (200 ultrasound scans), (Toshiba, Tokyo, Japan)were collected using a 7.5 MHz transducer. The measured cIMTs for L/R carotid were as follows (in mm):(i) AtheroCloud™ (0.8770.20, 0.7770.20) ; (ii) sonographer (0.9770.26, 0.8970.29) and (iii) manual(0.9070.20, 0.7970.20), respectively. The coefficient of correlation (CC) between sonographer and manualfor L/R cIMT was 0.74 (Po0.0001) and 0.65 (Po0.0001), while, between AtheroCloud™ and manual was 0.96 (Po0.0001) and 0.97 (Po0.0001), respectively. We observed that 91.15% of the population in AtheroCloud™ had a mean cIMT error less than 0.11 mm compared to sonographer’s 68.31%. The area under curve for receiving operating characteristics was 0.99 for AtheroCloud™ against 0.81 for sonographer. Our Framingham Risk Score stratified the population into three bins as follows: 39% in low-risk, 70.66% in mediumrisk and 10.66% in high-risk bins. Statistical tests were performed to demonstrate consistency, reliability and accuracy of the results. The proposed AtheroCloud™ system is completely reliable, automated, fast (3-5 seconds depending upon the image size having an internet speed of 180 Mbps), accurate, and e, and an intelligent, web-based clinical tool for multi- center clinical trials and routine telemedicine clinical care.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Klinika za infektivne bolesti "Dr Fran Mihaljević",
Zdravstveno veleučilište, Zagreb

Profili:

Avatar Url Klaudija Višković (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Saba, Luca; Sumit, Banchhor; Suri, Harman; Londhe, Narendra; Araki, Tadashi; Ikeda, Nobutaka; Višković, Klaudija; Shafique, Shoaib; Laird, John; Gupta, Ajay et al.
Accurate cloud-based smart IMT measurement, its validation and stroke risk stratification in carotid ultrasound: A web-based point-of-care tool for multicenter clinical trial // Computers in biology and medicine, 75 (2016), 217-234 doi:10.1016/j.compbiomed.2016.06.010 (međunarodna recenzija, članak, znanstveni)
Saba, L., Sumit, B., Suri, H., Londhe, N., Araki, T., Ikeda, N., Višković, K., Shafique, S., Laird, J. & Gupta, A. (2016) Accurate cloud-based smart IMT measurement, its validation and stroke risk stratification in carotid ultrasound: A web-based point-of-care tool for multicenter clinical trial. Computers in biology and medicine, 75, 217-234 doi:10.1016/j.compbiomed.2016.06.010.
@article{article, author = {Saba, Luca and Sumit, Banchhor and Suri, Harman and Londhe, Narendra and Araki, Tadashi and Ikeda, Nobutaka and Vi\v{s}kovi\'{c}, Klaudija and Shafique, Shoaib and Laird, John and Gupta, Ajay and Nicolaides, Andrew and Suri, Jajsit}, year = {2016}, pages = {217-234}, DOI = {10.1016/j.compbiomed.2016.06.010}, keywords = {Stroke, Carotid, Atherosclerosis, Ultrasound, Telemedicine, Cloud, cIMT, Routine}, journal = {Computers in biology and medicine}, doi = {10.1016/j.compbiomed.2016.06.010}, volume = {75}, issn = {0010-4825}, title = {Accurate cloud-based smart IMT measurement, its validation and stroke risk stratification in carotid ultrasound: A web-based point-of-care tool for multicenter clinical trial}, keyword = {Stroke, Carotid, Atherosclerosis, Ultrasound, Telemedicine, Cloud, cIMT, Routine} }
@article{article, author = {Saba, Luca and Sumit, Banchhor and Suri, Harman and Londhe, Narendra and Araki, Tadashi and Ikeda, Nobutaka and Vi\v{s}kovi\'{c}, Klaudija and Shafique, Shoaib and Laird, John and Gupta, Ajay and Nicolaides, Andrew and Suri, Jajsit}, year = {2016}, pages = {217-234}, DOI = {10.1016/j.compbiomed.2016.06.010}, keywords = {Stroke, Carotid, Atherosclerosis, Ultrasound, Telemedicine, Cloud, cIMT, Routine}, journal = {Computers in biology and medicine}, doi = {10.1016/j.compbiomed.2016.06.010}, volume = {75}, issn = {0010-4825}, title = {Accurate cloud-based smart IMT measurement, its validation and stroke risk stratification in carotid ultrasound: A web-based point-of-care tool for multicenter clinical trial}, keyword = {Stroke, Carotid, Atherosclerosis, Ultrasound, Telemedicine, Cloud, cIMT, Routine} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font