Multifunctional WAMPAC system concept for out-of-step protection based on synchrophasor measurements


Ivanković, Igor; Kuzle, Igor; Holjevac, Ninoslav
Multifunctional WAMPAC system concept for out-of-step protection based on synchrophasor measurements // International journal of electrical power & energy systems, 87 (2017), 77-88 doi:10.1016/j.ijepes.2016.11.005 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 843929 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Multifunctional WAMPAC system concept for out-of-step protection based on synchrophasor measurements

Autori
Ivanković, Igor ; Kuzle, Igor ; Holjevac, Ninoslav

Izvornik
International journal of electrical power & energy systems (0142-0615) 87 (2017); 77-88

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Multifunctional system protection ; synchrophasor measurements ; angle stability ; out-of-step conditions ; power angle key performance indicators (KPI)

Sažetak
Transmission network control and protection system can be enhanced using synchrophasor measurement data. Wide Area Monitoring, Protection and Control (WAMPAC) systems incorporate three levels of protection functions. The first layer is the basic relay protection, the second layer is the central system protection with wide area protection functions (WAP) and the final layer is the power system control level. Centralized protection can use new methods based on synchrophasor data. The phasor data benefits protection functions of both the second and the third layer Therefore, to investigate the operation of the different protection functions in a centralized system, a multifunctional Matlab simulation environment is developed and presented in this paper. The model is developed using the experience from the real-time operation and was additionally expanded with new function sets that are also described. Real-time operation measurements from various disturbances are used to validate the model. Validated model is then applied to perform a series of simulations of various events in different conditions in the transmission network, such as breaker operation, short circuit faults and power oscillations. Conducted simulations provide foundations and indicators for the development and definition of criteria needed to implement enhanced central protection system resilient to all disturbances.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
HRZZ-IP-2013-11-7766 - Fleksibilna energetska čvorišta u nisko ugljičnim naprednim elektroenergetskim mrežama (FENISG) (Kuzle, Igor, HRZZ ) ( CroRIS)

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Igor Kuzle (autor)

Avatar Url Igor Ivanković (autor)

Avatar Url Ninoslav Holjevac (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com

Citiraj ovu publikaciju:

Ivanković, Igor; Kuzle, Igor; Holjevac, Ninoslav
Multifunctional WAMPAC system concept for out-of-step protection based on synchrophasor measurements // International journal of electrical power & energy systems, 87 (2017), 77-88 doi:10.1016/j.ijepes.2016.11.005 (međunarodna recenzija, članak, znanstveni)
Ivanković, I., Kuzle, I. & Holjevac, N. (2017) Multifunctional WAMPAC system concept for out-of-step protection based on synchrophasor measurements. International journal of electrical power & energy systems, 87, 77-88 doi:10.1016/j.ijepes.2016.11.005.
@article{article, author = {Ivankovi\'{c}, Igor and Kuzle, Igor and Holjevac, Ninoslav}, year = {2017}, pages = {77-88}, DOI = {10.1016/j.ijepes.2016.11.005}, keywords = {Multifunctional system protection, synchrophasor measurements, angle stability, out-of-step conditions, power angle key performance indicators (KPI)}, journal = {International journal of electrical power and energy systems}, doi = {10.1016/j.ijepes.2016.11.005}, volume = {87}, issn = {0142-0615}, title = {Multifunctional WAMPAC system concept for out-of-step protection based on synchrophasor measurements}, keyword = {Multifunctional system protection, synchrophasor measurements, angle stability, out-of-step conditions, power angle key performance indicators (KPI)} }
@article{article, author = {Ivankovi\'{c}, Igor and Kuzle, Igor and Holjevac, Ninoslav}, year = {2017}, pages = {77-88}, DOI = {10.1016/j.ijepes.2016.11.005}, keywords = {Multifunctional system protection, synchrophasor measurements, angle stability, out-of-step conditions, power angle key performance indicators (KPI)}, journal = {International journal of electrical power and energy systems}, doi = {10.1016/j.ijepes.2016.11.005}, volume = {87}, issn = {0142-0615}, title = {Multifunctional WAMPAC system concept for out-of-step protection based on synchrophasor measurements}, keyword = {Multifunctional system protection, synchrophasor measurements, angle stability, out-of-step conditions, power angle key performance indicators (KPI)} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Uključenost u ostale bibliografske baze podataka::


  • INSPEC


Citati: