Pregled bibliografske jedinice broj: 842787
MRAS based estimation of stator resistance and rotor flux linkage of permanent magnet generator considering core losses
MRAS based estimation of stator resistance and rotor flux linkage of permanent magnet generator considering core losses // Proceedings of The 42nd Annual Conference of IEEE Industrial Electronics Society IECON 2016 / Carlo Cecati (ur.).
Firenza : München, 2016. str. 1-7 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 842787 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
MRAS based estimation of stator resistance and rotor flux linkage of permanent magnet generator considering core losses
Autori
Marković, Ivor ; Erceg, Igor ; Sumina, Damir
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of The 42nd Annual Conference of IEEE Industrial Electronics Society IECON 2016
/ Carlo Cecati - Firenza : München, 2016, 1-7
Skup
IECON 2016 The 42nd Annual Conference of IEEE Industrial Electronics Society
Mjesto i datum
Firenca, Italija, 24.10.2016. - 27.10.2016
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Permanent magnet synchronous generator ; MRAS ; Core losses ; Parameter identification
Sažetak
For maximization of efficiency of interior permanent magnet generators (IPMSG) and optimization of machine control correct parameters of the machine are needed. Parameters used in advanced control of the machine are stator resistance, magnetic flux linkage and inductances of d and q axes. Alongside them ohmic resistance that represents core losses can be employed to further increase efficiency of control. This work will focus on implementation of MRAS estimator that has adaptive models with and without taking into account core losses. Using Matlab Simulink simulations were conducted and comparison of estimators was made under change of current in d and q axis and different values of resistance that represents core losses. Results show that value of resistance that represents core losses influences estimated values of parameters and that it is beneficial to take into account core losses for efficient control of the machine.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
HRZZ-UIP-2013-11-7601 - Razvoj naprednih energetski učinkovitih struktura upravljanja generatorom sa stalnim magnetima bez mjernog člana (PMGEFC) (Sumina, Damir, HRZZ ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb