Pregled bibliografske jedinice broj: 842687
LOSS REDUCTION METHODS OF SALIENT POLE SYNCHRONOUS GENERATOR DAMPER WINDING BY MEANS OF SLOT SKEW
LOSS REDUCTION METHODS OF SALIENT POLE SYNCHRONOUS GENERATOR DAMPER WINDING BY MEANS OF SLOT SKEW // Set of Papers: CIGRE SESSION 46, from 21 till 26 August 2016, Paris
Pariz: Internarional Council on Large Electric Systems, 2016. str. A1 - 112, 8 str (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 842687 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
LOSS REDUCTION METHODS OF SALIENT POLE SYNCHRONOUS GENERATOR DAMPER WINDING BY MEANS OF SLOT SKEW
Autori
Študir, Josip ; Elez, Ante ; Petrinić, Marijan ; Petrinić, Miroslav
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Set of Papers: CIGRE SESSION 46, from 21 till 26 August 2016, Paris
/ - Pariz : Internarional Council on Large Electric Systems, 2016, A1 - 112, 8 str
Skup
CIGRE SESSION 46, from 21 till 26 August 2016, Paris
Mjesto i datum
Pariz, Francuska, 21.08.2016. - 26.08.2016
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Synchronous generator; electromagnetic calculations; dumper bar winding; slot skew; losses
Sažetak
Slot skew is applied as a method to increase the quality of armature winding voltage waveform of synchronous hydro generators. Skew that matches the region of one slot pitch is most effective in dampening of stator slot harmonics, but can in some production cases be hard to achieve. This is especially true for machines that have greater axial length. That is why other methods are commonly used to increase the voltage waveform quality of large hydro generators. One such method is based on the damper winding slot pitch choice that ensures reduction of stator slot harmonics from the main magnetic field. Appropriate placement of damper bars over the pole shoe does not represent a significant technological problem, and is much easier to manufacture then the slot skew or the fractional armature winding. The downside of damper slot pitch adjustment method is the increase of damper bar currents in steady state conditions of the generator, and therefore the increase of damper winding losses and the rotor temperature. To decrease damper winding currents for long term operating conditions and enable the generator pole shoe design with damper bars of smaller cross section, a combination of damper slot pitch and partial slot skew can be utilized. This paper gives insight on consequences that can occur on voltage waveform if slot skew doesn't not fully match the slot stator pitch, and the advantages that the above mentioned combined method gives on the design optimization of salient pole synchronous generator.