Pregled bibliografske jedinice broj: 84241
Suppression of shaft vibration at HPP Dubrava unit 1 based on detailled rotor diagnostics
Suppression of shaft vibration at HPP Dubrava unit 1 based on detailled rotor diagnostics // Hydro 2001: Opprortunities and Challenges
Sutton: The International Journal on Hydropowers & Dams, 2001. str. 287-290 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 84241 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Suppression of shaft vibration at HPP Dubrava unit 1 based on detailled rotor diagnostics
Autori
Dvekar, Đuro ; Bajić, Branko ; Bacinger, Ivan ; Sabolek, Josip ; Demirović, Muharem
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Hydro 2001: Opprortunities and Challenges
/ - Sutton : The International Journal on Hydropowers & Dams, 2001, 287-290
Skup
Hydro 2001: Opprortunities and Challenges
Mjesto i datum
Riva del Garda, Italija, 27.09.2001. - 29.09.2001
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
shaft; spider; rotor; vibration; diagnostics
Sažetak
The way used to suppress vibration on HPP Dubrava bulb unit 1 caused by loosening of the keyed spider-shaft joint is described. The spider was precisely positioned on the shaft. This step was based on the extensive diagnostic tests and a detailed analysis of rotor kinematics and dynamics. The spider is fixed by the elements that are resistive to the existing types of fretting.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika, Strojarstvo