Pregled bibliografske jedinice broj: 840596
Characterisation of the new sensor for anionic surfactant determination based on tetraoctadecylammonium-tetraphenylborate
Characterisation of the new sensor for anionic surfactant determination based on tetraoctadecylammonium-tetraphenylborate // Book of Abstracts, Special Issue of Bulletin of the Chemists and Technologists of Bosnia and Herzegovina
Sarajevo, 2016. str. 38-38 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 840596 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Characterisation of the new sensor for anionic surfactant determination based on tetraoctadecylammonium-tetraphenylborate
Autori
Petrušić, Sanja ; Samardžić, Mirela ; Sak-Bosnar, Milan
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Book of Abstracts, Special Issue of Bulletin of the Chemists and Technologists of Bosnia and Herzegovina
/ - Sarajevo, 2016, 38-38
Skup
2nd International Congress of Chemists and Chemical Engineers of Bosnia and Herzegovina
Mjesto i datum
Sarajevo, Bosna i Hercegovina, 21.10.2016. - 23.10.2016
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
anionic surfactant sensor; potentiometric titration; commercial products; effluents
Sažetak
Anionic surfactants are the most significant type of surfactants, commercially. The standard reference methods for their determination are methylene blue active substances method (MBAS) and two-phase titration. Although these methods are frequently applied, they suffer from many drowbacks such as lack of ability to be automated and miniaturized and use of toxic and carcinogenic organic solvents. Due to the fact that it is necessary to monitor anionic surfactants concentration in environment, as well as in industrial processes and products, there is a need to improve existing sensors and methods for their determination. A new liquid membrane type of anionic surfactant selective electrode based on tetraoctadecylammonium-tetraphenylborate (TODA-TPB) is constructed. Three electrodes with different percentage of electroactive material (1%, 3% and 5%) are compared. The best response characteristics and the highest jump in equivalence point during potentiometric titration of anionic surfactants exhibited electrode with 3% of electroactive material so that electrode is selected for further characterization. The selected sensor exhibits a Nernstian response for analyzed anionic surfactants (sodium dodecyl sulfate and sodium dodecylbenzenesulfonate) and excellent selectivity performance. The applicability of the sensor is demonstrated by succesfull determination of anionic surfactants in real samples (commercial detergents and effluents).
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Projekti:
HRZZ-IP-2013-11-9060 - Primjena nanomaterijala u izradi potenciometrijskih tenzidnih senzora za primjenu u industriji i zaštiti okoliša (NANOSENS) (Sak-Bosnar, Milan, HRZZ - 2013-11) ( CroRIS)
Ustanove:
Sveučilište u Osijeku - Odjel za kemiju