Pregled bibliografske jedinice broj: 83890
Influence of radiation Effect on The Measurement Relative Intensity in X-ray Emission Spectroscopy
Influence of radiation Effect on The Measurement Relative Intensity in X-ray Emission Spectroscopy // Book of Abstracts from 4th Mediterranean Basin Conference on Analytical Chemistry / Veber, Marijan (ur.).
Ljubljana: Slovensko kemijsko društvo, 2002. (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 83890 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Influence of radiation Effect on The Measurement Relative Intensity in X-ray Emission Spectroscopy
Autori
Novosel-Radović, Vjera ; Radović, Nikol ; Balen, Milka
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Book of Abstracts from 4th Mediterranean Basin Conference on Analytical Chemistry
/ Veber, Marijan - Ljubljana : Slovensko kemijsko društvo, 2002
Skup
4th Mediterranean Basin Conference on Analytical Chemistry
Mjesto i datum
Portorož, Slovenija, 15.09.2002. - 20.09.2002
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
x-ray emission spektrometry; radiation effect; relative intensity
Sažetak
It has been observed that standard samples, such as iron ore, sinters, mixture for sinter and blast furnace slag pressed into briquet with boric acid (ratio 1:3) diminished their wear resistance after radiation. Also, the measured intensities of analytical lines CaK alpha, SiK alpha and FeK alpha showed the deviation concerning the accuracy and reproducibility of measurement. To explain those deviations an investigation was undertaken to find out how to the measured intensities were affected by radiation effect. The model samples were used. They were prepared with calcit, quartz, boric acid and scale (mixture of iron compounds, more than 90 % Fe3O4). The components were ground and separed in fractions of different grain size by sieve. Parts of separeted fractions were irradiated for 30, 60, 90 and 120 minutes in the Philips semi-automatic x-ray spectrometer. Irradiated samples of boric acid were examined by sieve analysis, and each fraction was again subjected to irradiated and sieve analysis. The samples of different grain size: calcit, quartz, scale and boric acid were homogenized and briqueted using a Spex Al-holder. Measurement of analytical lines of CaK alpha, SiK alpha, FeK alpha were made on a Philips sequential semi automatic x-ray spectrometer. Secondary electron micrographs of non - irradiated boric acid were taken on scanning electron microscope. The values of the measure relative intensities and sieve analysis were treated mathematicaly. The analysis showed that differences in the accuracy and reproducibility of measurement of the relative intensities of analytical lines of CaK alpha, SiK alpha, FeK alpha were due to the heterogeneity effect as results of radiation effect on the binder boric acid.
Izvorni jezik
Engleski
Znanstvena područja
Geodezija, Metalurgija
POVEZANOST RADA
Ustanove:
Geodetski fakultet, Zagreb,
Metalurški fakultet, Sisak