Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 838399

Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM) with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies


Kasper, Manuel; Traxler, Lukas; Salopek, Jasmina; Grabmayr, Herwig; Ebner, Andreas; Kienberger, Ferry
Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM) with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies // Biosensors, 6 (2016), 2; 23, 13 doi:10.3390/bios6020023 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 838399 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM) with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies

Autori
Kasper, Manuel ; Traxler, Lukas ; Salopek, Jasmina ; Grabmayr, Herwig ; Ebner, Andreas ; Kienberger, Ferry

Izvornik
Biosensors (2079-6374) 6 (2016), 2; 23, 13

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
quartz crystal microbalance ; impedance analysis ; biosensing ; dissipation ; higher harmonics

Sažetak
We developed an impedance quartz crystal microbalance (QCM) approach with the ability to simultaneously record mass changes and calibrated energy dissipation with high sensitivity using an impedance analyzer. This impedance QCM measures frequency shifts and resistance changes of sensing quartz crystals very stable, accurately, and calibrated, thus yielding quantitative information on mass changes and dissipation. Resistance changes below 0.3 W were measured with corresponding dissipation values of 0.01 U (micro dissipation units). The broadband impedance capabilities allow measurements between 20 Hz and 120 MHz including higher harmonic modes of up to 11th order for a 10 MHz fundamental resonance frequency quartz crystal. We demonstrate the adsorbed mass, calibrated resistance, and quantitative dissipation measurements on two biological systems including the high affinity based avidin-biotin interaction and nano- assemblies of polyelectrolyte layers. The binding affinity of a protein-antibody interaction was determined. The impedance QCM is a versatile and simple method for accurate and calibrated resistance and dissipation measurements with broadband measurement capabilities for higher harmonics measurements.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Kemija, Biotehnologija



POVEZANOST RADA


Ustanove:
Prirodoslovno-matematički fakultet, Zagreb

Profili:

Avatar Url Jasmina Jukić (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada doi www.mdpi.com

Citiraj ovu publikaciju:

Kasper, Manuel; Traxler, Lukas; Salopek, Jasmina; Grabmayr, Herwig; Ebner, Andreas; Kienberger, Ferry
Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM) with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies // Biosensors, 6 (2016), 2; 23, 13 doi:10.3390/bios6020023 (međunarodna recenzija, članak, znanstveni)
Kasper, M., Traxler, L., Salopek, J., Grabmayr, H., Ebner, A. & Kienberger, F. (2016) Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM) with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies. Biosensors, 6 (2), 23, 13 doi:10.3390/bios6020023.
@article{article, author = {Kasper, Manuel and Traxler, Lukas and Salopek, Jasmina and Grabmayr, Herwig and Ebner, Andreas and Kienberger, Ferry}, year = {2016}, pages = {13}, DOI = {10.3390/bios6020023}, chapter = {23}, keywords = {quartz crystal microbalance, impedance analysis, biosensing, dissipation, higher harmonics}, journal = {Biosensors}, doi = {10.3390/bios6020023}, volume = {6}, number = {2}, issn = {2079-6374}, title = {Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM) with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies}, keyword = {quartz crystal microbalance, impedance analysis, biosensing, dissipation, higher harmonics}, chapternumber = {23} }
@article{article, author = {Kasper, Manuel and Traxler, Lukas and Salopek, Jasmina and Grabmayr, Herwig and Ebner, Andreas and Kienberger, Ferry}, year = {2016}, pages = {13}, DOI = {10.3390/bios6020023}, chapter = {23}, keywords = {quartz crystal microbalance, impedance analysis, biosensing, dissipation, higher harmonics}, journal = {Biosensors}, doi = {10.3390/bios6020023}, volume = {6}, number = {2}, issn = {2079-6374}, title = {Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM) with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies}, keyword = {quartz crystal microbalance, impedance analysis, biosensing, dissipation, higher harmonics}, chapternumber = {23} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Emerging Sources Citation Index (ESCI)
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka::


  • INSPEC


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font