Pregled bibliografske jedinice broj: 838148
Influence of Two Erbium Lasers on Micro Push-out Bond Strength of Prefabricated and Individually Formed Fiber-Reinforced Composite Posts
Influence of Two Erbium Lasers on Micro Push-out Bond Strength of Prefabricated and Individually Formed Fiber-Reinforced Composite Posts // Jorunal of Dental Research
Jeruzalem, Izrael, 2016. str. x-x (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 838148 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Influence of Two Erbium Lasers on Micro Push-out
Bond Strength of Prefabricated and Individually
Formed Fiber-Reinforced Composite Posts
Autori
Parčina Amižić, Ivana ; Miletić, Ivana ; Gabrić, Dragana ; Basso, Matteo ; Ionescu, Andrei C. ; Brambilla, Eugenio ; Baraba, Anja
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Jorunal of Dental Research
/ - , 2016, X-x
Skup
IADR/PER kongres, Jeruzalem, Izrael
Mjesto i datum
Jeruzalem, Izrael, 20.09.2016. - 22.09.2016
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
FRC post ; erbium lasers
Sažetak
The objective of this in vitro study was to examine the influence of two erbium lasers on bond strength of prefabricated and individually formed fiber reinforced composite (FRC) posts. One hundred twenty six single- rooted human teeth were decoronated, endodontically treated and after post space preparation on divided in two groups (n=63 per group) depending on the type of FRC posts, prefabricated GC Fiber Post and individually formed everStick Post. Each group was further subdivided into three groups (n=21 per group), according to the pretreatment protocol for post space preparation: irrigattion on with saline (control group), laser-acttivated irrigattion with Er:YAG and Er, Cr:YSGG laser. Finally, each group was subdivided into three subgroups (n=7) depending on the cement used: G-Cem LinkAce (GC, Tokyo, Japan), RelyX U200 (3M ESPE St.Paul, SAD), SpeedCem (Ivoclar Vivadent, Schaan, Liechtenstein). After cementation of FRC posts, specimens were perpendiculary sectioned into 1 mm thin sectiones and push-out test was performed. Statstical anaysis was performed on log- transformed data using factorial ANOVA at level of significance set at 5%. The bond strength values were not affected by the type of post or cement used (p≤0.05). Lower bond strength values were obtained for Er:YAG laser (3.27±1.58 MPa) in comparison to the control group (3.87±1.89 Mpa), (p≤0.05). There was no sta)s)cally significant difference in bond strength of both tested post groups in comparison to control group when Er, Cr:YSGG laser was used (p≤0.05). No sta)s)cally significant difference in bond strength for tested post groups was observed when two erbium lasers were compared (p≤0.05). Conclusions: The bond strength was affected by the type of erbium laser used and Er:YAG laser lowered the bond strength for both prefabricated and individually formed FRC posts.
Izvorni jezik
Engleski
Znanstvena područja
Dentalna medicina
POVEZANOST RADA
Ustanove:
Stomatološki fakultet, Zagreb
Profili:
Mate Babić
(autor)
Ivana Parčina Amižić
(autor)
Dragana Gabrić
(autor)
Anja Baraba
(autor)
Ivana Miletić
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE