APPLICABLE IMPORTANCE OF VIBRO_DIAGNOSTICS IN PREDICTABLE MAINTENANCE OF "NAISUS" AQUEDUCT SYSTEM


Milovančević, Miloš; Vračar, Ljubomir; Troha, Sanjin
APPLICABLE IMPORTANCE OF VIBRO_DIAGNOSTICS IN PREDICTABLE MAINTENANCE OF "NAISUS" AQUEDUCT SYSTEM // Machine Design (Novi Sad), 7 (2015), 3; 97-100 (podatak o recenziji nije dostupan, članak, znanstveni)


CROSBI ID: 824303 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
APPLICABLE IMPORTANCE OF VIBRO_DIAGNOSTICS IN PREDICTABLE MAINTENANCE OF "NAISUS" AQUEDUCT SYSTEM

Autori
Milovančević, Miloš ; Vračar, Ljubomir ; Troha, Sanjin

Izvornik
Machine Design (Novi Sad) (1821-1259) 7 (2015), 3; 97-100

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
water distribution; vibrodiagnostics; pumping power units

Sažetak
In order to secure the working order of mechanical systems, it is necessary to ensure a variety of supervision measures of working reliability. Basis of this control are supervision of vibrations and their measuring by electric devices. "Naissus" waterworks with its wells, intake system, adequate distribution and manifold network, pumping stations and water reservoirs - all represents the Nish Aqueduct System (NIVOS). It supplies with fresh water about 240000 people and very diverse industry of Nish municipality with 103377 cubic meters per day, making it 37732608 cubic meters per year. Important part of this complex system of water distribution to consumers is about fifty functional pumping stations. These pumping stations contain 115 pumping power units with different assignments. Use of vibrodiagnostics to provide predictable maintanance is a key segment in realization of the flawless work of pumping power units.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo, Temeljne tehničke znanosti



POVEZANOST RADA


Ustanove:
Tehnički fakultet, Rijeka

Profili:

Avatar Url Sanjin Troha (autor)


Citiraj ovu publikaciju:

Milovančević, Miloš; Vračar, Ljubomir; Troha, Sanjin
APPLICABLE IMPORTANCE OF VIBRO_DIAGNOSTICS IN PREDICTABLE MAINTENANCE OF "NAISUS" AQUEDUCT SYSTEM // Machine Design (Novi Sad), 7 (2015), 3; 97-100 (podatak o recenziji nije dostupan, članak, znanstveni)
Milovančević, M., Vračar, L. & Troha, S. (2015) APPLICABLE IMPORTANCE OF VIBRO_DIAGNOSTICS IN PREDICTABLE MAINTENANCE OF "NAISUS" AQUEDUCT SYSTEM. Machine Design (Novi Sad), 7 (3), 97-100.
@article{article, author = {Milovan\v{c}evi\'{c}, Milo\v{s} and Vra\v{c}ar, Ljubomir and Troha, Sanjin}, year = {2015}, pages = {97-100}, keywords = {water distribution, vibrodiagnostics, pumping power units}, journal = {Machine Design (Novi Sad)}, volume = {7}, number = {3}, issn = {1821-1259}, title = {APPLICABLE IMPORTANCE OF VIBRO\_DIAGNOSTICS IN PREDICTABLE MAINTENANCE OF "NAISUS" AQUEDUCT SYSTEM}, keyword = {water distribution, vibrodiagnostics, pumping power units} }
@article{article, author = {Milovan\v{c}evi\'{c}, Milo\v{s} and Vra\v{c}ar, Ljubomir and Troha, Sanjin}, year = {2015}, pages = {97-100}, keywords = {water distribution, vibrodiagnostics, pumping power units}, journal = {Machine Design (Novi Sad)}, volume = {7}, number = {3}, issn = {1821-1259}, title = {APPLICABLE IMPORTANCE OF VIBRO\_DIAGNOSTICS IN PREDICTABLE MAINTENANCE OF "NAISUS" AQUEDUCT SYSTEM}, keyword = {water distribution, vibrodiagnostics, pumping power units} }




Contrast
Increase Font
Decrease Font
Dyslexic Font