Ocular Aberrations and Corneal Thickness-Intraocular Pressure Relationship One Year after Laser in situ Keratomileusis (LASIK) Enhancement with An Aspheric Ablation Profile


Bohač, Maja; Antičić, Marija; Končarević, Mateja; Biščević, Alma; Cerović, Vesna; Gabrić, Nikica; Patel, Sudi
Ocular Aberrations and Corneal Thickness-Intraocular Pressure Relationship One Year after Laser in situ Keratomileusis (LASIK) Enhancement with An Aspheric Ablation Profile // Journal of clinical & experimental ophthalmology, 6 (2015), 5; 1-7 doi:10.4172/2155-9570.1000480 (podatak o recenziji nije dostupan, članak, znanstveni)


CROSBI ID: 821457 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Ocular Aberrations and Corneal Thickness-Intraocular Pressure Relationship One Year after Laser in situ Keratomileusis (LASIK) Enhancement with An Aspheric Ablation Profile

Autori
Bohač, Maja ; Antičić, Marija ; Končarević, Mateja ; Biščević, Alma ; Cerović, Vesna ; Gabrić, Nikica ; Patel, Sudi

Izvornik
Journal of clinical & experimental ophthalmology (2155-9570) 6 (2015), 5; 1-7

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Corneal thickness; High order aberrations (Hoas); Intraocular pressure (IOP); LASIK enhancement; Excimer laser; Wavefront; Wavelight allegretto

Sažetak
Objective: To evaluate the effect of an aspheric LASIK refractive enhancement performed by relifting the original flap on the higher order aberrations (HOA) of the eye and the relationship between central corneal thickness (CCT) and intra-ocular pressure (IOP). Methods: Consecutive case series of 30 eyes requiring refractive enhancement from 1804 uncomplicated primary LASIK procedures performed in 2012. Flap relift and wavefront optimized ablation (Wavelight Allegretto Eye Q 400 Hz excimer laser) were performed in all cases. Pre-and post-operative examination included Shack-Hartmann aberrometry for 3 mm and 5 mm pupil sizes, CCT and IOP. Postoperative results at 1 year were compared to baseline values. Results: Changes in average values of coma, spherical aberration (SA), trefoil, CCT and IOP were not significant. Linear regression revealed significant associations between change (y) in trefoil and pre-enhancement value of trefoil for 3 mm pupil (0.828x-0.045, r=0.722, p<0.001), coma and pre-enhancement value of coma for 5 mm pupil (y=0.281x-0.030, r=0.501, n=30, p=0.048), SA for 3 mm pupil compared with change in CT (y=0.0080-0.0009x, r=-0.378, p=0.0392), and SA for 5 mm pupil compared with change in CCT (y=0.0035x-0.0541, r=0.524, p=0.0029). Also there was a significant association between IOP and CCT both pre-(IOP=0.0313CT-3.3, r=0.740, p<0.0001) and post-enhancement (IOP=0.0243CT-0.018, r=0.675, p<0.0001). Conclusion: LASIK enhancement with an aspheric ablation profile did not significantly impact on the average values for HOAs, IOP or CCT. For individual cases, the likely shift in magnitude of coma, trefoil and SA can be estimated and, the change in SA is correlated with changes in CCT. The change in the abscissa value linking IOP with CCT may be an indication of changes in biomechanical properties of the cornea in the central region.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Rijeka,
Specijalna bolnica Svjetlost

Profili:

Avatar Url Mateja Jagić (autor)

Avatar Url Nikica Gabrić (autor)

Avatar Url Maja Bohač (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada doi www.omicsonline.org

Citiraj ovu publikaciju:

Bohač, Maja; Antičić, Marija; Končarević, Mateja; Biščević, Alma; Cerović, Vesna; Gabrić, Nikica; Patel, Sudi
Ocular Aberrations and Corneal Thickness-Intraocular Pressure Relationship One Year after Laser in situ Keratomileusis (LASIK) Enhancement with An Aspheric Ablation Profile // Journal of clinical & experimental ophthalmology, 6 (2015), 5; 1-7 doi:10.4172/2155-9570.1000480 (podatak o recenziji nije dostupan, članak, znanstveni)
Bohač, M., Antičić, M., Končarević, M., Biščević, A., Cerović, V., Gabrić, N. & Patel, S. (2015) Ocular Aberrations and Corneal Thickness-Intraocular Pressure Relationship One Year after Laser in situ Keratomileusis (LASIK) Enhancement with An Aspheric Ablation Profile. Journal of clinical & experimental ophthalmology, 6 (5), 1-7 doi:10.4172/2155-9570.1000480.
@article{article, author = {Boha\v{c}, Maja and Anti\v{c}i\'{c}, Marija and Kon\v{c}arevi\'{c}, Mateja and Bi\v{s}\v{c}evi\'{c}, Alma and Cerovi\'{c}, Vesna and Gabri\'{c}, Nikica and Patel, Sudi}, year = {2015}, pages = {1-7}, DOI = {10.4172/2155-9570.1000480}, keywords = {Corneal thickness, High order aberrations (Hoas), Intraocular pressure (IOP), LASIK enhancement, Excimer laser, Wavefront, Wavelight allegretto}, journal = {Journal of clinical and experimental ophthalmology}, doi = {10.4172/2155-9570.1000480}, volume = {6}, number = {5}, issn = {2155-9570}, title = {Ocular Aberrations and Corneal Thickness-Intraocular Pressure Relationship One Year after Laser in situ Keratomileusis (LASIK) Enhancement with An Aspheric Ablation Profile}, keyword = {Corneal thickness, High order aberrations (Hoas), Intraocular pressure (IOP), LASIK enhancement, Excimer laser, Wavefront, Wavelight allegretto} }
@article{article, author = {Boha\v{c}, Maja and Anti\v{c}i\'{c}, Marija and Kon\v{c}arevi\'{c}, Mateja and Bi\v{s}\v{c}evi\'{c}, Alma and Cerovi\'{c}, Vesna and Gabri\'{c}, Nikica and Patel, Sudi}, year = {2015}, pages = {1-7}, DOI = {10.4172/2155-9570.1000480}, keywords = {Corneal thickness, High order aberrations (Hoas), Intraocular pressure (IOP), LASIK enhancement, Excimer laser, Wavefront, Wavelight allegretto}, journal = {Journal of clinical and experimental ophthalmology}, doi = {10.4172/2155-9570.1000480}, volume = {6}, number = {5}, issn = {2155-9570}, title = {Ocular Aberrations and Corneal Thickness-Intraocular Pressure Relationship One Year after Laser in situ Keratomileusis (LASIK) Enhancement with An Aspheric Ablation Profile}, keyword = {Corneal thickness, High order aberrations (Hoas), Intraocular pressure (IOP), LASIK enhancement, Excimer laser, Wavefront, Wavelight allegretto} }

Citati: