Pregled bibliografske jedinice broj: 820990
Vector analysis of astigmatism before and after LASIK: a comparison of two different platforms for treatment of high astigmatism
Vector analysis of astigmatism before and after LASIK: a comparison of two different platforms for treatment of high astigmatism // Graefe's archive for clinical and experimental ophthalmology, 253 (2015), 12; 2325-2333 doi:10.1007/s00417-015-3177-x (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 820990 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Vector analysis of astigmatism before and after LASIK: a comparison of two different platforms for treatment of high astigmatism
Autori
Biščević, Alma ; Bohac, Maja ; Končarević, Mateja ; Antičić, Marija ; Dekaris, Iva ; Patel, Sudi
Izvornik
Graefe's archive for clinical and experimental ophthalmology (0721-832X) 253
(2015), 12;
2325-2333
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Astigmatism ; Excimer laser ; LASIK ; Vector analysis
Sažetak
PURPOSE: To compare the outcomes of astigmatic laser in- situ keratomileusis (LASIK) procedures between two different platforms using J0 and J45 vector analysis. METHODS: Patients were divided into four groups, depending on the type of astigmatism and laser platform on which they were treated. Astigmatism was between 2 and 7 diopters (D). One hundred and thirty-five patients with myopic astigmatism (246 eyes) and 102 patients with mixed astigmatism (172 eyes) underwent unremarkable LASIK correction on Wavelight Allegretto Eye-Q 400Hz and Schwind Amaris 750S laser platform. The preoperative and postoperative sphere, negative cylinder [C] and axis (ø) of manifest refractions were subjected to vector analysis by calculations of the standard J0 (cos [4π(ø-90)/360]xC/2) and J45 (sin[4π(ø-90)/360]xC/2). RESULTS: Reporting the key results, we found J0 significantly reduced after LASIK in both groups (p < 0.001) but not J45. There was no significant association between individual pairs of pre and postoperative J0 & J45 values. There was no significant difference between the outcomes of the two platforms. CONCLUSIONS: Wavelight Allegretto 400Hz and Schwind Amaris 750S showed excellent results for treating patients with astigmatism, regardless whether it is mixed or myopic astigmatism. The J45 did not reduce significantly possibly because of the low number of eyes with oblique astigmatism. There was no genuine difference post-operatively between groups treated on two different laser platforms according to the vector analyses.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Medicinski fakultet, Rijeka,
Specijalna bolnica Svjetlost
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE
Uključenost u ostale bibliografske baze podataka::
- MEDLINE