Sažetak
In this prospective study we wanted to report our experience and to evaluate the efficacy and safety of Ex-press Mini-Glaucoma Shunt implantation under a superficial scleral flap, as a newly and improved surgical technology in a treatment of POAG (Primary open-angle glaucoma) and refractory glaucoma. 44 eyes (35 patients) underwent an implantation of Ex-Press Mini Glaucoma Shunt. We had 21 patients with POAG (60%) and 14 patients with PEXG-pseudoexfoliation glaucoma (40%). The follow-up period was 8.62 + 7.48 months (range 2-22 months). Main outcome measures included postoperative IOP control, postoperative medications and early postoperative complications. The IOP was measured in the following postoperative time-points of 1 day, 1 week, 1, 3, 6, 9 and 12 months. The mean IOP values 1 year postoperatively were reduced for 52.8% compared to preoperative values and the use of medications were reduced for 77%. We had complications like postoperative hypotony (3.5%), choroidal ablation (7%), intraocular hemorrhage (3.5%) and postoperative shunt closure (3.5%). The Ex PRESS Mini Glaucoma Shunt implanted under a superficial scleral flap is relatively safe and effective surgical procedure and provides satisfactory IOP control and medication reduction. However, device related complications remain still a problem.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Rijeka,
Specijalna bolnica Svjetlost

Profili:

Avatar Url Nikica Gabrić (autor)


Citiraj ovu publikaciju:

Gavrić, Morena; Gabrić, Nikica; Jagić, Jurica; Čović, Ana
Clinical experience with Ex-press Mini Glaucoma Shunt implantation // Collegium antropologicum, 35 (2011), 2; 39-41 (recenziran, članak, stručni)
Gavrić, M., Gabrić, N., Jagić, J. & Čović, A. (2011) Clinical experience with Ex-press Mini Glaucoma Shunt implantation. Collegium antropologicum, 35 (2), 39-41.
@article{article, author = {Gavri\'{c}, Morena and Gabri\'{c}, Nikica and Jagi\'{c}, Jurica and \v{C}ovi\'{c}, Ana}, year = {2011}, pages = {39-41}, keywords = {Ex-Press Mini Glaucoma Shunt, glaucoma}, journal = {Collegium antropologicum}, volume = {35}, number = {2}, issn = {0350-6134}, title = {Clinical experience with Ex-press Mini Glaucoma Shunt implantation}, keyword = {Ex-Press Mini Glaucoma Shunt, glaucoma} }
@article{article, author = {Gavri\'{c}, Morena and Gabri\'{c}, Nikica and Jagi\'{c}, Jurica and \v{C}ovi\'{c}, Ana}, year = {2011}, pages = {39-41}, keywords = {Ex-Press Mini Glaucoma Shunt, glaucoma}, journal = {Collegium antropologicum}, volume = {35}, number = {2}, issn = {0350-6134}, title = {Clinical experience with Ex-press Mini Glaucoma Shunt implantation}, keyword = {Ex-Press Mini Glaucoma Shunt, glaucoma} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Social Science Citation Index (SSCI)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka::


  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font