Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 816576

Computed tomography: Influence of part position on measurement results


Horvatić, Amalija; Runje, Biserka; Novak, Igor
Computed tomography: Influence of part position on measurement results // Dimensional X-ray Computed Tomography Conference 2016
Teddington: National Physical Laboratory, 2016. str. 11-11 (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 816576 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Computed tomography: Influence of part position on measurement results

Autori
Horvatić, Amalija ; Runje, Biserka ; Novak, Igor

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Dimensional X-ray Computed Tomography Conference 2016 / - Teddington : National Physical Laboratory, 2016, 11-11

Skup
Dimensional X-ray Computed Tomography Conference 2016

Mjesto i datum
Teddington, Ujedinjeno Kraljevstvo, 10.05.2016

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Computed tomography; Influence parameters; Part position; Measurement results

Sažetak
Computed tomography (CT) is a relatively new method in the field of dimensional measurement. It is a non destructive, non tactile coordinate method for dimensional measurements. Its advantage compared to other coordinate measurement methods is that it provides insight into internal geometry of measured parts without destroying them. However, due to large number of influential factors, measurement uncertainty is not yet defined and measurement traceability is still not achieved. One of the approaches to achieve traceability is to identify and determine all influential factors as well as their impact on measurements. In this paper, one of the uncertainty components - the position of the measured part - was observed. Standard uncertainty was calculated based on observations obtained under repeatability and reproducibility conditions. Measurements were conducted in three different object orientations and repeated four times. In accordance with the document JCGM 100 201x cd (revised Guide to the expression of uncertainty in measurement) from the year 2015 the Bayesian approach was used to evaluate the type A standard uncertainty component. The test sample was an aluminium cylinder specially shaped and manufactured so that, apart from the dimensional characteristic (length), two geometrical characteristics (flatness and parallelism) were investigated. Scanning was conducted on Nikon XTH 225, while the measurements of the scanned model were done in the software Volume Graphics StudioMAX 2.2. Finally, the results were compared with those obtained using the tactile coordinate measurement machine. 

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb

Profili:

Avatar Url Biserka Runje (autor)

Avatar Url Amalija Horvatić Novak (autor)


Citiraj ovu publikaciju:

Horvatić, Amalija; Runje, Biserka; Novak, Igor
Computed tomography: Influence of part position on measurement results // Dimensional X-ray Computed Tomography Conference 2016
Teddington: National Physical Laboratory, 2016. str. 11-11 (poster, međunarodna recenzija, sažetak, znanstveni)
Horvatić, A., Runje, B. & Novak, I. (2016) Computed tomography: Influence of part position on measurement results. U: Dimensional X-ray Computed Tomography Conference 2016.
@article{article, author = {Horvati\'{c}, Amalija and Runje, Biserka and Novak, Igor}, year = {2016}, pages = {11-11}, keywords = {Computed tomography, Influence parameters, Part position, Measurement results}, title = {Computed tomography: Influence of part position on measurement results}, keyword = {Computed tomography, Influence parameters, Part position, Measurement results}, publisher = {National Physical Laboratory}, publisherplace = {Teddington, Ujedinjeno Kraljevstvo} }
@article{article, author = {Horvati\'{c}, Amalija and Runje, Biserka and Novak, Igor}, year = {2016}, pages = {11-11}, keywords = {Computed tomography, Influence parameters, Part position, Measurement results}, title = {Computed tomography: Influence of part position on measurement results}, keyword = {Computed tomography, Influence parameters, Part position, Measurement results}, publisher = {National Physical Laboratory}, publisherplace = {Teddington, Ujedinjeno Kraljevstvo} }




Contrast
Increase Font
Decrease Font
Dyslexic Font