The influence of field size and off-axis distance on photoneutron spectra of the 18 MV Siemens Oncor linear accelerator beam


Brkić, Hrvoje; Ivković, Ana; Kasabašić, Mladen; Poje Sovilj, Marina; Jurković, Slaven; Štimac, Damir; Rubin, Otmar; Faj, Dario
The influence of field size and off-axis distance on photoneutron spectra of the 18 MV Siemens Oncor linear accelerator beam // Radiation measurements, 93 (2016), 28-34 doi:10.1016/j.radmeas.2016.07.002 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 815374 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The influence of field size and off-axis distance on photoneutron spectra of the 18 MV Siemens Oncor linear accelerator beam

Autori
Brkić, Hrvoje ; Ivković, Ana ; Kasabašić, Mladen ; Poje Sovilj, Marina ; Jurković, Slaven ; Štimac, Damir ; Rubin, Otmar ; Faj, Dario

Izvornik
Radiation measurements (1350-4487) 93 (2016); 28-34

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Radiotherapy ; neutron contamination ; Monte Carlo

Sažetak
At present, high energy electron linear accelerators (LINACs) producing photons with energies higher than 10 MeV have a wide use in radiotherapy (RT). However, in these beams fast neutrons could be generated, which results in undesired contamination of the therapeutic beams. These neutrons affect the shielding requirements in RT rooms and also increase the out-of-field radiation dose to patients. The neutron flux becomes even more important when high numbers of monitor units are used, as in the intensity modulated radiotherapy. Herein, to evaluate the exposure of patients and medical personnel, it is important to determine the full radiation field correctly. A model of the dual photon beam medical LINAC, Siemens ONCOR, used at the University Hospital Centre of Osijek was built using the MCNP611 code. We tuned the model according to measured photon percentage depth dose curves and profiles. Only 18 MV photon beams were modeled. The dependence of neutron dose equivalent and energy spectrum on field size and off-axis distance in the patient plane was analyzed. The neutron source strength (Q) defined as a number of neutrons coming from the head of the treatment unit per x-ray dose (Gy) delivered at the isocenter was calculated and found to be 1.12·1012 neutrons per photon Gy at isocenter. The simulation showed that the neutron flux increases with increasing field size but field size has almost no effect on the shape of neutron dose profiles. The calculated neutron dose equivalent of different field sizes was between 1 and 3 mSv per photon Gy at isocenter. The mean energy changed from 0.21 MeV to 0.63 MeV with collimator opening from 0x0 cm2 to 40x40 cm2. At the 50 cm off-axis the change was less pronounced. According to the results, it is reasonable to conclude that the neutron dose equivalent to the patient is proportional to the photon beam-on time as suggested before. Since the beam-on time is much higher when advanced radiotherapy techniques are used to fulfill high conformity demands, this makes the neutron flux determination even more important. We also showed that the neutron energy in the patient plane significantly changes with field size. This can introduce significant uncertainty in dosimetry of neutrons due to strong dependence of the neutron detector response on the neutron energy in the interval 0.1-5 MeV.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Projekti:
HR.3.2.01-0283

Ustanove:
Medicinski fakultet, Rijeka,
Klinički bolnički centar Osijek,
Medicinski fakultet, Osijek,
Klinički bolnički centar Rijeka,
Sveučilište u Osijeku - Odjel za fiziku

Citiraj ovu publikaciju:

Brkić, Hrvoje; Ivković, Ana; Kasabašić, Mladen; Poje Sovilj, Marina; Jurković, Slaven; Štimac, Damir; Rubin, Otmar; Faj, Dario
The influence of field size and off-axis distance on photoneutron spectra of the 18 MV Siemens Oncor linear accelerator beam // Radiation measurements, 93 (2016), 28-34 doi:10.1016/j.radmeas.2016.07.002 (međunarodna recenzija, članak, znanstveni)
Brkić, H., Ivković, A., Kasabašić, M., Poje Sovilj, M., Jurković, S., Štimac, D., Rubin, O. & Faj, D. (2016) The influence of field size and off-axis distance on photoneutron spectra of the 18 MV Siemens Oncor linear accelerator beam. Radiation measurements, 93, 28-34 doi:10.1016/j.radmeas.2016.07.002.
@article{article, author = {Brki\'{c}, Hrvoje and Ivkovi\'{c}, Ana and Kasaba\v{s}i\'{c}, Mladen and Poje Sovilj, Marina and Jurkovi\'{c}, Slaven and \v{S}timac, Damir and Rubin, Otmar and Faj, Dario}, year = {2016}, pages = {28-34}, DOI = {10.1016/j.radmeas.2016.07.002}, keywords = {Radiotherapy, neutron contamination, Monte Carlo}, journal = {Radiation measurements}, doi = {10.1016/j.radmeas.2016.07.002}, volume = {93}, issn = {1350-4487}, title = {The influence of field size and off-axis distance on photoneutron spectra of the 18 MV Siemens Oncor linear accelerator beam}, keyword = {Radiotherapy, neutron contamination, Monte Carlo} }
@article{article, author = {Brki\'{c}, Hrvoje and Ivkovi\'{c}, Ana and Kasaba\v{s}i\'{c}, Mladen and Poje Sovilj, Marina and Jurkovi\'{c}, Slaven and \v{S}timac, Damir and Rubin, Otmar and Faj, Dario}, year = {2016}, pages = {28-34}, DOI = {10.1016/j.radmeas.2016.07.002}, keywords = {Radiotherapy, neutron contamination, Monte Carlo}, journal = {Radiation measurements}, doi = {10.1016/j.radmeas.2016.07.002}, volume = {93}, issn = {1350-4487}, title = {The influence of field size and off-axis distance on photoneutron spectra of the 18 MV Siemens Oncor linear accelerator beam}, keyword = {Radiotherapy, neutron contamination, Monte Carlo} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font