Pregled bibliografske jedinice broj: 813354
Morphological characterization of ex situ prepared bismuth film electrodes and their application in electroanalytical determination of the biomolecules
Morphological characterization of ex situ prepared bismuth film electrodes and their application in electroanalytical determination of the biomolecules // Journal of solid state electrochemistry, 20 (2016), 8; 2241-2250 doi:10.1007/s10008-016-3234-3 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 813354 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Morphological characterization of ex situ prepared bismuth film electrodes and their application in electroanalytical determination of the biomolecules
Autori
Vladislavić, Nives ; Buzuk Marijo ; Brinić, Slobodan ; Buljac Maša ; Bralić, Marija
Izvornik
Journal of solid state electrochemistry (1432-8488) 20
(2016), 8;
2241-2250
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
bismuth film electrode ; film morphology ; biomolecule ; electroanalytical
Sažetak
A study on the preparation and characterization of the potentiostaticly prepared bismuth films (BiFs), in order to obtain satisfactory electroanalytical tool, is presented. BiFs formed on glassy carbon were characterized by electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The dependence of the BiFs properties upon electrolytes composition and electrochemical parameters are discussed and diagnostic criteria that allow estimation of the BiF morphology are proposed. Analytical performance data of the formed BiF electrodes were obtained by their application to the determination of glutathione (GSH) and folic acid (FA) using square-wave cathodic stripping voltammetry. The dependence of the analytical performance of the formed BiFs on their specific surface areas, along with their different morphology is discussed. Adequate method and parameters for the electrochemical formation of optimal BiF, in order to fulfill the analytical requirements, are proposed. The best analytical performance was obtained with films formed from acetic buffer solution spiked with EDTA, as a consequence of the improved surface coverage and most arranged homogenous structure of the film. This electrode displays a linear response range toward GSH with estimated detection limit of 0.005 μM and sensitivity of 3.28 μA μM–1 for linear range of 0.01 to 0.1 μM. Also, the utilization of the BiF electrode for the determination of FA was demonstrated by direct electroreduction of FA.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Ustanove:
Kemijsko-tehnološki fakultet, Split
Profili:
Marija Bralić
(autor)
Nives Vladislavić
(autor)
Marijo Buzuk
(autor)
Slobodan Brinić
(autor)
Maša Buljac
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus