Pregled bibliografske jedinice broj: 811778

Validation of methods performance for routine biochemistry analytes at Cobas 6000 analyzer series module c501


Šupak Smolčić V, Bilić-Zulle L, Fišić E
Validation of methods performance for routine biochemistry analytes at Cobas 6000 analyzer series module c501 // Biochemia medica : časopis hrvatskoga društva medicinskih biokemičara, 21 (2011), 2; 182-190 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 811778 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Validation of methods performance for routine biochemistry analytes at Cobas 6000 analyzer series module c501

Autori
Šupak Smolčić V, Bilić-Zulle L, Fišić E

Izvornik
Biochemia medica : časopis hrvatskoga društva medicinskih biokemičara (1330-0962) 21 (2011), 2; 182-190

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
validation study; chemistry techniques; analytical; Cobas 6000 analyzer; total error; Passing and Bablock regression

Sažetak
Introduction: Cobas 6000 (Roche, Germany) is biochemistry analyzer for spectrophotometric, immunoturbidimetric and ion-selective determination of biochemical analytes. Hereby we present analytical validation with emphasis on method performance judgment for routine operation. Materials and methods: Validation was made for 30 analytes (metabolites, enzymes, trace elements, specific proteins and electrolytes). Research included determination of within-run (N = 20) and between-run imprecision (N = 30), inaccuracy (N = 30) and method comparison with routine analyzer (Beckman Coulter AU640) (N = 50). For validation of complete analytical process we calculated total error (TE). Results were judged according to quality specification criteria given by European Working Group. Results: Within-run imprecision CVs were all below 5% except for cholesterol, triglycerides, IgA and IgM. Between-run CVs for all analytes were below 10%. Analytes that did not meet the required specifications for imprecision were: total protein, albumin, calcium, sodium, chloride, immunoglobulins and HDL cholesterol. Analytes that did not fulfill requirements for inaccuracy were: total protein, calcium, sodium and chloride. Analytes that deviated from quality specifications for total error were: total protein, albumin, calcium, sodium, chloride and IgM. Passing-Bablok regression analysis provided linear equation and 95% confidence interval for intercept and slope. Complete accordance with routine analyzer Beckman Coulter AU640 showed small number of analytes. Other analytes showed small proportional and/or small constant difference and therefore need to be adjusted for routine operation. Conclusions: Regarding low CV values, tested analyzer has satisfactory accuracy and precision and is extremely stable. Except for analytes that are coherent on both analyzers, some analytes require adjustments of slope and intercept for complete accordance.

Izvorni jezik
Engleski

Znanstvena područja
Javno zdravstvo i zdravstvena zaštita



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Rijeka

Profili:

Avatar Url Lidija Bilić-Zulle (autor)

Citiraj ovu publikaciju:

Šupak Smolčić V, Bilić-Zulle L, Fišić E
Validation of methods performance for routine biochemistry analytes at Cobas 6000 analyzer series module c501 // Biochemia medica : časopis hrvatskoga društva medicinskih biokemičara, 21 (2011), 2; 182-190 (međunarodna recenzija, članak, znanstveni)
Šupak Smolčić V, Bilić-Zulle L, Fišić E (2011) Validation of methods performance for routine biochemistry analytes at Cobas 6000 analyzer series module c501. Biochemia medica : časopis hrvatskoga društva medicinskih biokemičara, 21 (2), 182-190.
@article{article, year = {2011}, pages = {182-190}, keywords = {validation study, chemistry techniques, analytical, Cobas 6000 analyzer, total error, Passing and Bablock regression}, journal = {Biochemia medica : \v{c}asopis hrvatskoga dru\v{s}tva medicinskih biokemi\v{c}ara}, volume = {21}, number = {2}, issn = {1330-0962}, title = {Validation of methods performance for routine biochemistry analytes at Cobas 6000 analyzer series module c501}, keyword = {validation study, chemistry techniques, analytical, Cobas 6000 analyzer, total error, Passing and Bablock regression} }
@article{article, year = {2011}, pages = {182-190}, keywords = {validation study, chemistry techniques, analytical, Cobas 6000 analyzer, total error, Passing and Bablock regression}, journal = {Biochemia medica : \v{c}asopis hrvatskoga dru\v{s}tva medicinskih biokemi\v{c}ara}, volume = {21}, number = {2}, issn = {1330-0962}, title = {Validation of methods performance for routine biochemistry analytes at Cobas 6000 analyzer series module c501}, keyword = {validation study, chemistry techniques, analytical, Cobas 6000 analyzer, total error, Passing and Bablock regression} }