THE METHOD OF CALIBRATION OF He-Ne LASER USING THE NPL IODINE STABILIZED He-Ne LASER WITH WAVELENGTH AT 633 nm
THE METHOD OF CALIBRATION OF He-Ne LASER USING THE NPL IODINE STABILIZED He-Ne LASER WITH WAVELENGTH AT 633 nm // 18th International Research/Expert Conference ” Trends in the Development of Machinery and Associated Technology” / Dr. Sabahudin Ekinović, Dr. Senay Yalcin, Dr. Joan Vivancos Calvet (ur.).
Budimpešta, Mađarska, 2014. str. 293-296 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 805673 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
THE METHOD OF CALIBRATION OF He-Ne LASER USING THE NPL IODINE STABILIZED He-Ne LASER WITH WAVELENGTH AT 633 nm
Autori
Bošnjaković, Alen ; Hazim, Bašić.
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
18th International Research/Expert Conference ” Trends in the Development of Machinery and Associated Technology”
/ Dr. Sabahudin Ekinović, Dr. Senay Yalcin, Dr. Joan Vivancos Calvet - , 2014, 293-296
Skup
18th International Research/Expert Conference ” Trends in the Development of Machinery and Associated Technology”
Mjesto i datum
Budimpešta, Mađarska, 10.09.2014. - 12.09.2014
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
length standard ; measure uncertainties ; beat frequency ; iodine stabilized He-Ne laser
Sažetak
NPL iodine stabilized He-Ne laser at wavelength 633 nm is intended for work with the 2nd class lasers in visible spectrum, respectively, it is a laser with the output energy that is lower than 1mW and operates at wavelength from 400 nm to 700 nm. This referent standard is designed to be tabilized to the b21 component of the 6-3 P (33) iodine transition. This transition is listed in the CIPM recommendation for practical realization of the meter. NPL iodine stabilized He-Ne laser was used for calibration of He-Ne laser. The technique for dissemination unit of the length on the highest metrology level which is used for calibration of stabilized He-Ne lasers is called beat frequency. In the experimental part of work the practical mode of conducting calibration of frequency stabilized He-Ne Laser, respectively, determination of its referent frequency with the estimation uncertainty of measurement was done. Additionally, parameters that have influence on measuring results were estimated.