Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 797745

Calibration of piezocones for investigations in soft soils and demands for accuracy of the equipments


Mulabdić, Mensur; Eskilson, Sören; Larsson, Rolf
Calibration of piezocones for investigations in soft soils and demands for accuracy of the equipments, 1990. (izvještaj).


CROSBI ID: 797745 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Calibration of piezocones for investigations in soft soils and demands for accuracy of the equipments

Autori
Mulabdić, Mensur ; Eskilson, Sören ; Larsson, Rolf

Izvornik
Varia No. 270, Swedish Geotechnical Institue

Vrsta, podvrsta
Ostale vrste radova, izvještaj

Godina
1990

Ključne riječi
accuracy; calibration; soft rock; soil penetration test; temperature

Sažetak
This report deals with the calibration of cone penetrometers which should be performed before they are used in soft soils. It aims to describe the level of accuracy that can be obtained in the test results, to explain how this is achieved and to outline the working principles of the equipment and its inherent sources of error. It was written for the companies and staff performing this type of test, the manufacturers of the equipment, and for engineers interpreting and using the results. The investigations form part of a larger project exploring the use of new in situ testing devices for investigations in loose to medium soils. The report is divided into 4 main sections: a) basic calibration ; 2) calibration of pore pressure response ; 3) calibration of temperature effects, and 4) calibration of seismic cones.

Izvorni jezik
Engleski

Znanstvena područja
Građevinarstvo



POVEZANOST RADA


Profili:

Avatar Url Mensur Mulabdić (autor)


Citiraj ovu publikaciju:

Mulabdić, Mensur; Eskilson, Sören; Larsson, Rolf
Calibration of piezocones for investigations in soft soils and demands for accuracy of the equipments, 1990. (izvještaj).
Mulabdić, M., Eskilson, S. & Larsson, R. (1990) Calibration of piezocones for investigations in soft soils and demands for accuracy of the equipments. Varia No. 270, Swedish Geotechnical Institue. Izvještaj.
@unknown{unknown, author = {Mulabdi\'{c}, Mensur and Eskilson, S\"{o}ren and Larsson, Rolf}, year = {1990}, keywords = {accuracy, calibration, soft rock, soil penetration test, temperature}, title = {Calibration of piezocones for investigations in soft soils and demands for accuracy of the equipments}, keyword = {accuracy, calibration, soft rock, soil penetration test, temperature} }
@unknown{unknown, author = {Mulabdi\'{c}, Mensur and Eskilson, S\"{o}ren and Larsson, Rolf}, year = {1990}, keywords = {accuracy, calibration, soft rock, soil penetration test, temperature}, title = {Calibration of piezocones for investigations in soft soils and demands for accuracy of the equipments}, keyword = {accuracy, calibration, soft rock, soil penetration test, temperature} }




Contrast
Increase Font
Decrease Font
Dyslexic Font