A comparison of two-dimensional and three-dimensional conformal plans for intact left breast radiotherapy


Domijan, Dalibor; Prpić, Maja; Diklić, Ana
A comparison of two-dimensional and three-dimensional conformal plans for intact left breast radiotherapy // South east Europe technology in radiation technology
Zagreb, Hrvatska, 2015. (predavanje, međunarodna recenzija, neobjavljeni rad, znanstveni)


CROSBI ID: 793625 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
A comparison of two-dimensional and three-dimensional conformal plans for intact left breast radiotherapy

Autori
Domijan, Dalibor ; Prpić, Maja ; Diklić, Ana

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, neobjavljeni rad, znanstveni

Skup
South east Europe technology in radiation technology

Mjesto i datum
Zagreb, Hrvatska, 06.11.2015. - 08.11.2015

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
radiotherapy; breast cancer

Sažetak
Implementation of advanced radiation therapy techniques in clinical practice can greatly improve tumour control and normal tissue sparing. Radiation after surgery improves survival from breast cancer, but it can increase the risk of mortality from heart disease and secondary lung cancer. At University Hospital Rijeka (UHR) radiation therapy of intact breast is performed using 2D and since 2008, 3D treatment planning technique. The aim of this study is to compare 2D with 3D breast plan in breast conserving radiotherapy. Two isodose plans were calculated for each patient involved in this study. 2D and 3D plans were calculated by treatment planing system XiO 5.0, Elekta. For both plans, the volume receiving lover than 95% and greater then 105% of the reference dose were determinated as well as the volume of lung recieving ≤20Gy. Results are analyzed using program package Statistica, StatSoft and will be presented. Implementing 3D CRT into breast radiation therapy has resulted in better dose homogeneity as well as sparing of organs of risk. This increases the probability of tumour control and decreases the probability of late side-effects of radiation.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Temeljne medicinske znanosti, Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Klinički bolnički centar Rijeka

Profili:

Avatar Url Ana Božanić (autor)

Citiraj ovu publikaciju:

Domijan, Dalibor; Prpić, Maja; Diklić, Ana
A comparison of two-dimensional and three-dimensional conformal plans for intact left breast radiotherapy // South east Europe technology in radiation technology
Zagreb, Hrvatska, 2015. (predavanje, međunarodna recenzija, neobjavljeni rad, znanstveni)
Domijan, D., Prpić, M. & Diklić, A. (2015) A comparison of two-dimensional and three-dimensional conformal plans for intact left breast radiotherapy. U: South east Europe technology in radiation technology.
@article{article, author = {Domijan, Dalibor and Prpi\'{c}, Maja and Dikli\'{c}, Ana}, year = {2015}, keywords = {radiotherapy, breast cancer}, title = {A comparison of two-dimensional and three-dimensional conformal plans for intact left breast radiotherapy}, keyword = {radiotherapy, breast cancer}, publisherplace = {Zagreb, Hrvatska} }
@article{article, author = {Domijan, Dalibor and Prpi\'{c}, Maja and Dikli\'{c}, Ana}, year = {2015}, keywords = {radiotherapy, breast cancer}, title = {A comparison of two-dimensional and three-dimensional conformal plans for intact left breast radiotherapy}, keyword = {radiotherapy, breast cancer}, publisherplace = {Zagreb, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font