Parameters affecting on the reduction factor in pedestrian load models based on pulsating stationary force
Parameters affecting on the reduction factor in pedestrian load models based on pulsating stationary force // SPB 2015 Proceedings / Tornabene, Francesco (ur.).
Bolonja: Societa Editrice Escalapio, 2015. str. 18-19 (predavanje, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 776303 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Parameters affecting on the reduction factor in pedestrian load models based on pulsating stationary force
Autori
Štimac Grandić, Ivana ; Grandić, Davor ; Berić, Nikola
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
SPB 2015 Proceedings
/ Tornabene, Francesco - Bolonja : Societa Editrice Escalapio, 2015, 18-19
ISBN
978-88-7488-886-3
Skup
International Conference on Shells, Plates and Beams SPB 2015
Mjesto i datum
Bologna, Italija, 09.09.2015. - 11.09.2015
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
pedestrian bridge; pedestrian dynamic load model
Sažetak
Single pedestrian load model is defined, in general, in two ways: as a pulsating force moving over the bridge deck with a certain constant speed, or as a pulsating stationary force acting at the most adverse position of the bridge deck. Although it is easier to obtain the maximum acceleration due to pulsating stationary force it is necessary to establish the stationary load model which produces the same dynamic response of a structure as the moving load model. In this paper, the reduction factor is determined as the ratio of maximum accelerations due to the same model of moving pulsating force and stationary pulsating force. The reduction factors are calculated for bridge structural system of simple supported and fixed beam, span length of 15 m and 20 m, structural natural vertical frequency form 1 Hz to 5 Hz (in steps of 0.4 Hz), structural damping of 0, 5%, 1%, 1, 5%, 2%. From conducted analyses it can be concluded that changes in structural frequency does not affect the reduction factor, while changes in structural damping, structural system and span length affect the reduction factor as follows: the reduction factor increases with increasing in structural damping, the reduction factor is greater for longer spans, the reduction factors for fixed beam are smaller than the corresponding values for simply supported beam. Also, it can be seen that constant value of the reduction factor which can be found in some codes or guides can greatly overestimate of underestimate the maximum deck acceleration due to single pedestrian load model.