Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 772699

A gas ionisation detector in the axial (Bragg) geometry used for the Time-of-Flight Elastic Recoil Detection Analysis


Siketić, Zdravko; Skukan, Natko; Bogdanović Radović, Ivančica
A gas ionisation detector in the axial (Bragg) geometry used for the Time-of-Flight Elastic Recoil Detection Analysis // Review of scientific instruments, 86 (2015), 083301-1 doi:10.1063/1.4927605 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 772699 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
A gas ionisation detector in the axial (Bragg) geometry used for the Time-of-Flight Elastic Recoil Detection Analysis

Autori
Siketić, Zdravko ; Skukan, Natko ; Bogdanović Radović, Ivančica

Izvornik
Review of scientific instruments (0034-6748) 86 (2015); 083301-1

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Gas detector; mass resolution; Energy resolution; TOF-ERDA

Sažetak
In this paper Time-of-Flight Elastic Recoil Detection Analysis (TOF-ERDA) spectrometer with a newly constructed gas ionization detector (GID) for energy detection is presented. The detector is designed in the axial (Bragg) geometry with a 3x3 array of 50 nm thick Si3N4 membranes as an entrance window. 40 mbar isobutane gas was sufficient to stop a 30 MeV primary iodine beam as well as all recoils in the detector volume. Spectrometer and detector performances were determined showing significant improvement in the mass and energy resolution respectively, comparing to the spectrometer with a standard silicon particle detector for an energy measurements.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Ustanove:
Institut "Ruđer Bošković", Zagreb

Poveznice na cjeloviti tekst rada:

doi scitation.aip.org

Citiraj ovu publikaciju:

Siketić, Zdravko; Skukan, Natko; Bogdanović Radović, Ivančica
A gas ionisation detector in the axial (Bragg) geometry used for the Time-of-Flight Elastic Recoil Detection Analysis // Review of scientific instruments, 86 (2015), 083301-1 doi:10.1063/1.4927605 (međunarodna recenzija, članak, znanstveni)
Siketić, Z., Skukan, N. & Bogdanović Radović, I. (2015) A gas ionisation detector in the axial (Bragg) geometry used for the Time-of-Flight Elastic Recoil Detection Analysis. Review of scientific instruments, 86, 083301-1 doi:10.1063/1.4927605.
@article{article, author = {Siketi\'{c}, Zdravko and Skukan, Natko and Bogdanovi\'{c} Radovi\'{c}, Ivan\v{c}ica}, year = {2015}, pages = {083301-1-083301-6}, DOI = {10.1063/1.4927605}, keywords = {Gas detector, mass resolution, Energy resolution, TOF-ERDA}, journal = {Review of scientific instruments}, doi = {10.1063/1.4927605}, volume = {86}, issn = {0034-6748}, title = {A gas ionisation detector in the axial (Bragg) geometry used for the Time-of-Flight Elastic Recoil Detection Analysis}, keyword = {Gas detector, mass resolution, Energy resolution, TOF-ERDA} }
@article{article, author = {Siketi\'{c}, Zdravko and Skukan, Natko and Bogdanovi\'{c} Radovi\'{c}, Ivan\v{c}ica}, year = {2015}, pages = {083301-1-083301-6}, DOI = {10.1063/1.4927605}, keywords = {Gas detector, mass resolution, Energy resolution, TOF-ERDA}, journal = {Review of scientific instruments}, doi = {10.1063/1.4927605}, volume = {86}, issn = {0034-6748}, title = {A gas ionisation detector in the axial (Bragg) geometry used for the Time-of-Flight Elastic Recoil Detection Analysis}, keyword = {Gas detector, mass resolution, Energy resolution, TOF-ERDA} }