Pregled bibliografske jedinice broj: 759910
SCALE6.1 HYBRID SHIELDING METHODOLOGY FOR THE SPENT FUEL DRY STORAGE
SCALE6.1 HYBRID SHIELDING METHODOLOGY FOR THE SPENT FUEL DRY STORAGE // Proceedings of the 10th Symposium of the CROATIAN RADIATION PROTECTION ASSOCIATION / Petrinec, Branko ; Bituh, Tomislav ; Milić, Mirta ; Kopjar, Nevenka (ur.).
Zagreb: CROATIAN RADIATION PROTECTION ASSOCIATION, 2015. str. 408-413 (predavanje, nije recenziran, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 759910 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
SCALE6.1 HYBRID SHIELDING METHODOLOGY FOR THE SPENT FUEL DRY STORAGE
Autori
Matijević, Mario ; Pevec, Dubravko ; Trontl, Krešimir
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 10th Symposium of the CROATIAN RADIATION PROTECTION ASSOCIATION
/ Petrinec, Branko ; Bituh, Tomislav ; Milić, Mirta ; Kopjar, Nevenka - Zagreb : CROATIAN RADIATION PROTECTION ASSOCIATION, 2015, 408-413
Skup
10th Symposium of the CROATIAN RADIATION PROTECTION ASSOCIATION with international participation
Mjesto i datum
Šibenik, Hrvatska, 15.04.2015. - 17.04.2015
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Nije recenziran
Ključne riječi
Shielding; SCALE6.1; Monte Carlo; cask; FW-CADIS; dose rates
Sažetak
The SCALE6.1/MAVRIC hybrid deterministic- stochastic shielding methodology was used for dose rates calculation of the generic spent fuel dry storage installation. The neutron-gamma dose rates around the cask array were calculated over a large problem domain in order to determine the boundary of the controlled area. The FW-CADIS methodology, based on the deterministic forward and adjoint solution over the phase-space, was used for optimized, global Monte Carlo results over the mesh tally. The cask inventory was modeled as homogenized material corresponding to 20 fuel assemblies from a standard mid-sized PWR reactor. The global simulation model was an array of 32 casks in 2 rows with concrete foundations and external air, which makes a large spatial domain for shielding calculations. The dose rates around the casks were determined using FW-CADIS method with weighted adjoint source and mesh tally covering a portion of spatial domain of interest. The conservatively obtained dose rates give the upper boundary, since the activation reduction of sources was not taken into account when sequential filling of the dry storage will start. The effective area of the dry storage installation can be additionally reduced with lowering concrete foundation under the ground, embankment raising, and with extra concrete walls, that would additionally lower the dominant gamma dose rates.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
HRZZ-UIP-2013-11-3522 - Razvoj paketa računalskih programa za naprednu analizu štitova od gama i neutronskog zračenja (DOCPAGANSA) (Trontl, Krešimir, HRZZ ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb