Serum delipidation but not high-speed centrifugation is effective enough in clearing lipemia interference in serum lipase activity measurement


Radišić Biljak, Vanja; Božičević, Sandra; Krhač, Maja; Vučić Lovrenčić, Marijana
Serum delipidation but not high-speed centrifugation is effective enough in clearing lipemia interference in serum lipase activity measurement // Clinical Chemistry and Laboratory Medicine / Plebani, Mario (ur.).
Porto, Portugal, 2015. str. eA1-eA89 (poster, međunarodna recenzija, sažetak, stručni)


CROSBI ID: 759048 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Serum delipidation but not high-speed centrifugation is effective enough in clearing lipemia interference in serum lipase activity measurement

Autori
Radišić Biljak, Vanja ; Božičević, Sandra ; Krhač, Maja ; Vučić Lovrenčić, Marijana

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
Clinical Chemistry and Laboratory Medicine / Plebani, Mario - , 2015, EA1-eA89

Skup
3rd EFLM-BD Conference on Preanalytical Phase

Mjesto i datum
Porto, Portugal, 20.03.2015. - 21.03.2015

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
acute pancreatitis; lipase; lipid interference; high-speed centrifugation; delipidation

Sažetak
Background: Acute pancreatitis is commonly followed by hypertriglyceridemia. Most current diagnostic guidelines indicate that lipase should be preferred over amylase. However, grossly lipemic samples may interfere with routine laboratory methods for measurement of serum lipase activity. We aimed to evaluate the accuracy of lipase activity measurement by a method with declared lipemia interference in lipemic samples cleared by two different techniques: high speed centrifugation and delipidation using alpha- cyclodextrin (non- ionic natural macrocyclic polymer of glucose). Materials and methods: Thirty-four lipemic serum samples with triglyceride concentration range of 4.27 to 124.6 mmol/L were used in this study. Lipase activity was measured by two measuring principles: Roche Lipase colorimetric method (elective reference laboratory method accurate for lipemic samples), in native lipemic samples on Roche Cobas Integra 400 plus analyzer. Beckman Coulter colorimetric method (lipemia interference >10% above 700 mg/dL Intralipid) in native lipemic samples, and in two serum aliquots cleared of lipemia on Beckman Coulter AU400 analyzer. The results were compared using Bland & Altman plot. Interference of triglycerides on bias was checked by linear regression. All results were analyzed using MedCalc 9.4.2.0 statistical software (MedCalc Software bvba, Mariakerke, Belgium). Results: Bland & Altman plot revealed statistically significant bias between the two compared procedures measured in lipemic samples (differences (%): -36.35, 95% CI = -50.5834 to -22.1214) and aliquots cleared by high speed centrifugation (differences (%): -22.1744, 95% CI = -33.7913 to -10.5575). However, there was no statistically or clinically significant bias between the lipase activity measured in aliquots cleared by serum delipidation (differences (%):-4.1871, 95% CI = -9.7848 to 1.4107) nor it was affected by varying triglyceride levels (R2 = 0.03692, P=0.276). Conclusions: Serum lipase activity can be accurately measured using Beckman Coulter colorimetric method in grossly lipemic plasma samples cleared of lipemia by serum delipidation.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Klinička bolnica "Merkur"

Citiraj ovu publikaciju:

Radišić Biljak, Vanja; Božičević, Sandra; Krhač, Maja; Vučić Lovrenčić, Marijana
Serum delipidation but not high-speed centrifugation is effective enough in clearing lipemia interference in serum lipase activity measurement // Clinical Chemistry and Laboratory Medicine / Plebani, Mario (ur.).
Porto, Portugal, 2015. str. eA1-eA89 (poster, međunarodna recenzija, sažetak, stručni)
Radišić Biljak, V., Božičević, S., Krhač, M. & Vučić Lovrenčić, M. (2015) Serum delipidation but not high-speed centrifugation is effective enough in clearing lipemia interference in serum lipase activity measurement. U: Plebani, M. (ur.)Clinical Chemistry and Laboratory Medicine.
@article{article, author = {Radi\v{s}i\'{c} Biljak, Vanja and Bo\v{z}i\v{c}evi\'{c}, Sandra and Krha\v{c}, Maja and Vu\v{c}i\'{c} Lovren\v{c}i\'{c}, Marijana}, editor = {Plebani, M.}, year = {2015}, pages = {eA1-eA89}, keywords = {acute pancreatitis, lipase, lipid interference, high-speed centrifugation, delipidation}, title = {Serum delipidation but not high-speed centrifugation is effective enough in clearing lipemia interference in serum lipase activity measurement}, keyword = {acute pancreatitis, lipase, lipid interference, high-speed centrifugation, delipidation}, publisherplace = {Porto, Portugal} }
@article{article, author = {Radi\v{s}i\'{c} Biljak, Vanja and Bo\v{z}i\v{c}evi\'{c}, Sandra and Krha\v{c}, Maja and Vu\v{c}i\'{c} Lovren\v{c}i\'{c}, Marijana}, editor = {Plebani, M.}, year = {2015}, pages = {eA1-eA89}, keywords = {acute pancreatitis, lipase, lipid interference, high-speed centrifugation, delipidation}, title = {Serum delipidation but not high-speed centrifugation is effective enough in clearing lipemia interference in serum lipase activity measurement}, keyword = {acute pancreatitis, lipase, lipid interference, high-speed centrifugation, delipidation}, publisherplace = {Porto, Portugal} }

Časopis indeksira:


  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font