Pregled bibliografske jedinice broj: 75515
Comparison of two SH-based methods for estimation of metallothionein level in the digestive gland of naturally occurring mussels, Mytilus galloprovincialis
Comparison of two SH-based methods for estimation of metallothionein level in the digestive gland of naturally occurring mussels, Mytilus galloprovincialis // International Journal of Environmental Analytical Chemistry, 83 (2003), 3; 219-231 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 75515 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Comparison of two SH-based methods for estimation of metallothionein level in the digestive gland of naturally occurring mussels, Mytilus galloprovincialis
Autori
Ivanković, Dušica ; Pavičić, Jasenka ; Raspor, Biserka ; Falnoga, Ingrid ; Tušek-Žnidarič, Magda
Izvornik
International Journal of Environmental Analytical Chemistry (0306-7319) 83
(2003), 3;
219-231
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Metallothionein; MT quantification; Mytilus galloprovincialis; biomarker; biomonitoring
Sažetak
Two methods for the evaluation of MT level in M.galloprovincialis digestive gland homogenate extract, polarographic and spectrophotometric, were compared in combination with sample subjected to heat treatment (at 70oC and 85oC) as well as to solvent precipitation. Spectrophotometric measurements ranging within 0.081- 0.144 mg MTg-1 were at least one order of magnitude lower in comparison with the polarographic ones (2.21-2.88 mg MTg-1) depending on the particular sample treatment as well as two specific reagents and reference standards applied. Sephadex G-75 column chromatography of the differently treated samples and subsequent polarographic analysis in the pooled elution fractions indicated that a level of non-MT interfering thiolic component in homogenate extract may be accounted for more than 50% of the total polarographic signal, irrespective of a method of sample treatment applied. Consequently, the large discrepancy between methods could not be attributed only to the sample treatment procedures but more likely to certain not entirely explained analytical problems, particulary calibration with appropriated reference standard.
Izvorni jezik
Engleski
Znanstvena područja
Geologija, Kemija, Biologija
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
Uključenost u ostale bibliografske baze podataka::
- Chemical Abstracts