Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 750724

ULTRASONIC METHOD FOR TESTING OF POWER TRANSFORMERS


Brezak, Danijel; Filipović-Grčić, Dalibor
ULTRASONIC METHOD FOR TESTING OF POWER TRANSFORMERS // Proceedings of the 3rd International Colloquium Transformer Research and Asset Management, Split, Croatia, October 15 – 17, 2014
Split, Hrvatska, 2014. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 750724 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
ULTRASONIC METHOD FOR TESTING OF POWER TRANSFORMERS

Autori
Brezak, Danijel ; Filipović-Grčić, Dalibor

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the 3rd International Colloquium Transformer Research and Asset Management, Split, Croatia, October 15 – 17, 2014 / - , 2014

Skup
3rd International Colloquium Transformer Research and Asset Management, Split, Croatia, October 15 – 17, 2014

Mjesto i datum
Split, Hrvatska, 15.10.2014. - 17.10.2014

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
diagnostics; power transformer; partial discharges; ultrasound; acoustic emission

Sažetak
Ultrasonic method of detecting PD is based on the fact that the electrical energy of the PD transforms in a mechanical energy, an ultrasonic acoustic wave that spreads through the transformer to the tank wall. From time difference of wave detection on different sensors, a possible location of the source can be estimated. Ultrasonic method can detect other transformer deficiencies such as loose contacts and local overheating of oil (T>200°C). Three case studies are given in this paper. The first case was where DGA indicates the thermal problem in the oil and the result of ultrasonic testing points at OLTC contacts. In the second case an ultrasonic method was performed after electrical method detected high levels of PD at voltages much lower than the nominal. Ultrasonic method detected non-grounded parts of the returning limb electrostatic screen. In the third case, a failure of transformer, namely a breakdown from the HV bushing end shield, initiated a series of tests on similar transformers installed at the same substation. The assumption was that PD occurred in the shied epoxy insulation and eventually caused the breakdown.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
KONČAR - Institut za elektrotehniku d.d.

Profili:

Avatar Url Dalibor Filipović-Grčić (autor)


Citiraj ovu publikaciju:

Brezak, Danijel; Filipović-Grčić, Dalibor
ULTRASONIC METHOD FOR TESTING OF POWER TRANSFORMERS // Proceedings of the 3rd International Colloquium Transformer Research and Asset Management, Split, Croatia, October 15 – 17, 2014
Split, Hrvatska, 2014. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Brezak, D. & Filipović-Grčić, D. (2014) ULTRASONIC METHOD FOR TESTING OF POWER TRANSFORMERS. U: Proceedings of the 3rd International Colloquium Transformer Research and Asset Management, Split, Croatia, October 15 – 17, 2014.
@article{article, author = {Brezak, Danijel and Filipovi\'{c}-Gr\v{c}i\'{c}, Dalibor}, year = {2014}, pages = {10 str.}, keywords = {diagnostics, power transformer, partial discharges, ultrasound, acoustic emission}, title = {ULTRASONIC METHOD FOR TESTING OF POWER TRANSFORMERS}, keyword = {diagnostics, power transformer, partial discharges, ultrasound, acoustic emission}, publisherplace = {Split, Hrvatska} }
@article{article, author = {Brezak, Danijel and Filipovi\'{c}-Gr\v{c}i\'{c}, Dalibor}, year = {2014}, pages = {10 str.}, keywords = {diagnostics, power transformer, partial discharges, ultrasound, acoustic emission}, title = {ULTRASONIC METHOD FOR TESTING OF POWER TRANSFORMERS}, keyword = {diagnostics, power transformer, partial discharges, ultrasound, acoustic emission}, publisherplace = {Split, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font