Pregled bibliografske jedinice broj: 74458
Stripping Voltammetry
Stripping Voltammetry // Electroanalytical Methods / Scholz, Fritz (ur.).
Heidelberg: Springer, 2002. str. 191-210
CROSBI ID: 74458 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Stripping Voltammetry
Autori
Lovrić, Milivoj
Vrsta, podvrsta i kategorija rada
Poglavlja u knjigama, ostalo
Knjiga
Electroanalytical Methods
Urednik/ci
Scholz, Fritz
Izdavač
Springer
Grad
Heidelberg
Godina
2002
Raspon stranica
191-210
ISBN
3-540-42229-3
Ključne riječi
stripping voltammetry
Sažetak
Electrochemical stripping means the oxidative or reductive removal of atoms, ions or compounds from an electrode surface (or from the electrode body, as in case of liquid mercury electrodes with dissolved metals) [1-5]. Generally, these atoms, ions or compounds have been preliminary immobilized on the surface of an inert electrode (or within it) as the result of a preconcentration step, while the products of the electrochemical stripping will dissolve in the electrolytic solution. Often the product of the electrochemical stripping is identical with the analyte before the preconcentration. However, there are exemptions to these rules. Electroanalytical stripping methods comprise two steps: first, the accumulation of a dissolved analyte onto, or in the working electrode, and second, the subsequent stripping of the accumulated substance by a voltammetric [3,5], potentiometric [6,7] or coulometric [8] technique. In stripping voltammetry the condition is that there are two independent linear relationships: the first one between the activity of accumulated substance and the concentration of analyte in the sample, and the second one between the maximum stripping current and the accumulated substance activity. Hence, a cumulative linear relationship between the maximum response and the analyte concentration exists. However, the electrode capacity for the analyte accumulation is limited and the condition of linearity is satisfied only well below the electrode saturation. For this reason stripping voltammetry is used mainly in trace analysis. The limit of detection depends on the factor of proportionality between the activity of the accumulated substance and the bulk concentration of the analyte. This factor is a constant in the case of a chemical accumulation, but for the electrochemical accumulation it depends on the electrode potential. The factor of proportionality between the maximum stripping current and the analyte concentration is rarely known exactly. In fact, it is frequently ignored. For the analysis it suffices to establish the linear relationship empirically. The slope of this relationship may vary from one sample to another because of different influences of the matrix. In this case the concentration of the analyte is determined by the method of standard additions [1]. After measuring the response of the sample, the concentration of the analyte is deliberately increased by adding a certain volume of its standard solution. The response is measured again, and this procedure is repeated three or four times. The unknown concentration is determined by extrapolation of the regression line to the concentration axis [9]. However, in many analytical methods the final measurement is performed in a standard matrix that allows the construction of a calibration plot. Still, the slope of this plot depends on the active area of the working electrode surface. Each solid electrode needs a separate calibration plot, and that plot must be checked from time to time because of possible deterioration of the electrode surface [2].
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA