Safety of screening procedures with hand-held metal detectors among patients with implanted cardiac rhythm devices : a cross-sectional analysis


Jilek, C.; Tzeis, S.; Vražić, Hrvoje; Semmler, V.; Andrikopoulos, G.; Reents, T.; Fichtner, S.; Ammar, S.; Rassias, I.; Theodorakis, G. et al.
Safety of screening procedures with hand-held metal detectors among patients with implanted cardiac rhythm devices : a cross-sectional analysis // Annals of internal medicine, 155 (2011), 9; 587-592 doi:10.7326/0003-4819-155-9-201111010-00005 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 739116 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Safety of screening procedures with hand-held metal detectors among patients with implanted cardiac rhythm devices : a cross-sectional analysis

Autori
Jilek, C. ; Tzeis, S. ; Vražić, Hrvoje ; Semmler, V. ; Andrikopoulos, G. ; Reents, T. ; Fichtner, S. ; Ammar, S. ; Rassias, I. ; Theodorakis, G. ; Weber, S. ; Hessling, G. ; Deisenhofer, I. ; Kolb, C.

Izvornik
Annals of internal medicine (0003-4819) 155 (2011), 9; 587-592

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
cardiac rhythm devices; safety

Sažetak
Case reports suggest that the hand-held metal detectors used for security screening generate electromagnetic fields that may interfere with pacemaker and implantable cardioverter-defibrillator (ICD) function. Objective was to assess changes in function of pacemakers and ICDs after exposure to hand-held metal detectors. Design: Cross-sectional study. Setting: Two medical centers in Europe. 388 patients (209 with pacemakers and 179 with ICDs) presenting for routine follow-up of device function between September 2009 and December 2010. Abnormalities on electrocardiography suggestive of rhythm device malfunction (pacing inhibition, loss of capture, inappropriate mode switch, ventricular oversensing, and spontaneous reprogramming) after 30 seconds of exposure to 2 widely used hand-held metal detectors with a maximal electromagnetic flux density of 6.3 µT. No change in device function, including pacing or sensing abnormalities or device reprogramming, was observed in any patient. The study included a convenience sample of patients, and the number of different device models tested was small. Testing was conducted in 2 clinic settings. Hand-held metal detectors did not affect the function of pacemakers or ICDs in this sample. The use of hand-held metal detectors for security screening is probably safe for patients with pacemakers and ICDs, but these findings require confirmation.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Zagreb,
Klinička bolnica "Dubrava",
Sveučilište u Zagrebu

Profili:

Avatar Url Hrvoje Vražić (autor)

Poveznice na cjeloviti tekst rada:

doi annals.org

Citiraj ovu publikaciju:

Jilek, C.; Tzeis, S.; Vražić, Hrvoje; Semmler, V.; Andrikopoulos, G.; Reents, T.; Fichtner, S.; Ammar, S.; Rassias, I.; Theodorakis, G. et al.
Safety of screening procedures with hand-held metal detectors among patients with implanted cardiac rhythm devices : a cross-sectional analysis // Annals of internal medicine, 155 (2011), 9; 587-592 doi:10.7326/0003-4819-155-9-201111010-00005 (međunarodna recenzija, članak, znanstveni)
Jilek, C., Tzeis, S., Vražić, H., Semmler, V., Andrikopoulos, G., Reents, T., Fichtner, S., Ammar, S., Rassias, I. & Theodorakis, G. (2011) Safety of screening procedures with hand-held metal detectors among patients with implanted cardiac rhythm devices : a cross-sectional analysis. Annals of internal medicine, 155 (9), 587-592 doi:10.7326/0003-4819-155-9-201111010-00005.
@article{article, author = {Jilek, C. and Tzeis, S. and Vra\v{z}i\'{c}, Hrvoje and Semmler, V. and Andrikopoulos, G. and Reents, T. and Fichtner, S. and Ammar, S. and Rassias, I. and Theodorakis, G. and Weber, S. and Hessling, G. and Deisenhofer, I. and Kolb, C.}, year = {2011}, pages = {587-592}, DOI = {10.7326/0003-4819-155-9-201111010-00005}, keywords = {cardiac rhythm devices, safety}, journal = {Annals of internal medicine}, doi = {10.7326/0003-4819-155-9-201111010-00005}, volume = {155}, number = {9}, issn = {0003-4819}, title = {Safety of screening procedures with hand-held metal detectors among patients with implanted cardiac rhythm devices : a cross-sectional analysis}, keyword = {cardiac rhythm devices, safety} }
@article{article, author = {Jilek, C. and Tzeis, S. and Vra\v{z}i\'{c}, Hrvoje and Semmler, V. and Andrikopoulos, G. and Reents, T. and Fichtner, S. and Ammar, S. and Rassias, I. and Theodorakis, G. and Weber, S. and Hessling, G. and Deisenhofer, I. and Kolb, C.}, year = {2011}, pages = {587-592}, DOI = {10.7326/0003-4819-155-9-201111010-00005}, keywords = {cardiac rhythm devices, safety}, journal = {Annals of internal medicine}, doi = {10.7326/0003-4819-155-9-201111010-00005}, volume = {155}, number = {9}, issn = {0003-4819}, title = {Safety of screening procedures with hand-held metal detectors among patients with implanted cardiac rhythm devices : a cross-sectional analysis}, keyword = {cardiac rhythm devices, safety} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font