Chloride-selective liquid-membrane electrodes based on lipophilic methyl-tri-N-alkyl-ammonium compounds and their applicability to blood serum measurements


Hartman, K.; Luterotti, Svjetlana; Osswald, H.F.; Oehme, M.; Meier, P.C.; Ammann, D.; Simon, W.
Chloride-selective liquid-membrane electrodes based on lipophilic methyl-tri-N-alkyl-ammonium compounds and their applicability to blood serum measurements // Mikrochimica acta (1966), 70 (1978), 3/4; 235-246 doi:10.1007/BF01201614 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 728747 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Chloride-selective liquid-membrane electrodes based on lipophilic methyl-tri-N-alkyl-ammonium compounds and their applicability to blood serum measurements

Autori
Hartman, K. ; Luterotti, Svjetlana ; Osswald, H.F. ; Oehme, M. ; Meier, P.C. ; Ammann, D. ; Simon, W.

Izvornik
Mikrochimica acta (1966) (0026-3672) 70 (1978), 3/4; 235-246

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Chloride-selective electrode ; liquid membrane ; methyl-tri-N-alkyl-ammonium compounds ; blood serum

Sažetak
Several pure methyltrialkylammonium chlorides were synthesized and evaluated as chloride-selective components in liquid-membrane electrodes. The selectivities, stabilities and lifetimes of these PVC-based electrodes have been shown to be sensitive to the combination of ammonium compound and plasticizer used ; the membrane composition has been optimized for chloride activity measurements in blood serum. The inherent suitability of the system for applications to blood serum is borne out by the reproducibilities achieved, which compare well with those of popular analytical techniques for chloride ion, as long as contact with aqueous calibration solution is evaded.

Izvorni jezik
Engleski

Znanstvena područja
Kemija, Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb

Profili:

Avatar Url Svjetlana Luterotti (autor)

Poveznice na cjeloviti tekst rada:

doi link.springer.com

Citiraj ovu publikaciju:

Hartman, K.; Luterotti, Svjetlana; Osswald, H.F.; Oehme, M.; Meier, P.C.; Ammann, D.; Simon, W.
Chloride-selective liquid-membrane electrodes based on lipophilic methyl-tri-N-alkyl-ammonium compounds and their applicability to blood serum measurements // Mikrochimica acta (1966), 70 (1978), 3/4; 235-246 doi:10.1007/BF01201614 (međunarodna recenzija, članak, znanstveni)
Hartman, K., Luterotti, S., Osswald, H., Oehme, M., Meier, P., Ammann, D. & Simon, W. (1978) Chloride-selective liquid-membrane electrodes based on lipophilic methyl-tri-N-alkyl-ammonium compounds and their applicability to blood serum measurements. Mikrochimica acta (1966), 70 (3/4), 235-246 doi:10.1007/BF01201614.
@article{article, author = {Hartman, K. and Luterotti, Svjetlana and Osswald, H.F. and Oehme, M. and Meier, P.C. and Ammann, D. and Simon, W.}, year = {1978}, pages = {235-246}, DOI = {10.1007/BF01201614}, keywords = {Chloride-selective electrode, liquid membrane, methyl-tri-N-alkyl-ammonium compounds, blood serum}, journal = {Mikrochimica acta (1966)}, doi = {10.1007/BF01201614}, volume = {70}, number = {3/4}, issn = {0026-3672}, title = {Chloride-selective liquid-membrane electrodes based on lipophilic methyl-tri-N-alkyl-ammonium compounds and their applicability to blood serum measurements}, keyword = {Chloride-selective electrode, liquid membrane, methyl-tri-N-alkyl-ammonium compounds, blood serum} }
@article{article, author = {Hartman, K. and Luterotti, Svjetlana and Osswald, H.F. and Oehme, M. and Meier, P.C. and Ammann, D. and Simon, W.}, year = {1978}, pages = {235-246}, DOI = {10.1007/BF01201614}, keywords = {Chloride-selective electrode, liquid membrane, methyl-tri-N-alkyl-ammonium compounds, blood serum}, journal = {Mikrochimica acta (1966)}, doi = {10.1007/BF01201614}, volume = {70}, number = {3/4}, issn = {0026-3672}, title = {Chloride-selective liquid-membrane electrodes based on lipophilic methyl-tri-N-alkyl-ammonium compounds and their applicability to blood serum measurements}, keyword = {Chloride-selective electrode, liquid membrane, methyl-tri-N-alkyl-ammonium compounds, blood serum} }