Comparative study between lag screw and miniplate fixation for straight midline mandibular osteotomy.


Dediol, Emil; Čvrljević, Igor; Dobranić, Marijan; Uglešić, Vedran
Comparative study between lag screw and miniplate fixation for straight midline mandibular osteotomy. // International journal of oral and maxillofacial surgery, 43 (2014), 4; 399-404 doi:10.1016/j.ijom.2013.09.003 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 726191 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparative study between lag screw and miniplate fixation for straight midline mandibular osteotomy.

Autori
Dediol, Emil ; Čvrljević, Igor ; Dobranić, Marijan ; Uglešić, Vedran

Izvornik
International journal of oral and maxillofacial surgery (0901-5027) 43 (2014), 4; 399-404

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
lag screw; mandible fixation; mandible osteosynthesis; mandibulotomy; miniplate

Sažetak
The mandibular swing approach is a surgical approach for the resection of malignant lesions localized in the posterior oral cavity and oropharynx. We analyzed 15 years of experience with fixation of the straight midline mandibulotomy and compared two fixation methods: lag screws and miniplates. A total of 117 patients underwent a straight midline mandibulotomy during the study period ; 85 had fixation with two lag screws and 32 with two miniplates. The overall complication rate was low and there was no significant difference in complication rate regarding the fixation method (9% for miniplates vs. 7% for lag screws). The most serious complication over the whole study period was non union, which occurred in only two patients, followed by orocutaneous fistula and infection. Radiotherapy did not cause serious complications and is not regarded as hazardous in midline mandibulotomy patients. We conclude that lag screw fixation is at least as safe as miniplate fixation, but because of better fragment compression, offers faster bone healing.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti, Dentalna medicina



POVEZANOST RADA


Projekti:
065-1080057-0431 - Ispitivanje čimbenika kvalitete života bolesnika s intraoralnim karcinomom (Uglešić, Vedran, MZOS ) ( CroRIS)
108-1080057-0043 - Nacionalni model kliničke baze podataka u maksilofacijalnoj onkologiji (Virag, Mihajlo, MZOS ) ( CroRIS)

Ustanove:
Stomatološki fakultet, Zagreb,
Medicinski fakultet, Zagreb,
Klinička bolnica "Dubrava"

Profili:

Avatar Url Emil Dediol (autor)

Avatar Url Vedran Uglešić (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com

Citiraj ovu publikaciju:

Dediol, Emil; Čvrljević, Igor; Dobranić, Marijan; Uglešić, Vedran
Comparative study between lag screw and miniplate fixation for straight midline mandibular osteotomy. // International journal of oral and maxillofacial surgery, 43 (2014), 4; 399-404 doi:10.1016/j.ijom.2013.09.003 (međunarodna recenzija, članak, znanstveni)
Dediol, E., Čvrljević, I., Dobranić, M. & Uglešić, V. (2014) Comparative study between lag screw and miniplate fixation for straight midline mandibular osteotomy.. International journal of oral and maxillofacial surgery, 43 (4), 399-404 doi:10.1016/j.ijom.2013.09.003.
@article{article, author = {Dediol, Emil and \v{C}vrljevi\'{c}, Igor and Dobrani\'{c}, Marijan and Ugle\v{s}i\'{c}, Vedran}, year = {2014}, pages = {399-404}, DOI = {10.1016/j.ijom.2013.09.003}, keywords = {lag screw, mandible fixation, mandible osteosynthesis, mandibulotomy, miniplate}, journal = {International journal of oral and maxillofacial surgery}, doi = {10.1016/j.ijom.2013.09.003}, volume = {43}, number = {4}, issn = {0901-5027}, title = {Comparative study between lag screw and miniplate fixation for straight midline mandibular osteotomy.}, keyword = {lag screw, mandible fixation, mandible osteosynthesis, mandibulotomy, miniplate} }
@article{article, author = {Dediol, Emil and \v{C}vrljevi\'{c}, Igor and Dobrani\'{c}, Marijan and Ugle\v{s}i\'{c}, Vedran}, year = {2014}, pages = {399-404}, DOI = {10.1016/j.ijom.2013.09.003}, keywords = {lag screw, mandible fixation, mandible osteosynthesis, mandibulotomy, miniplate}, journal = {International journal of oral and maxillofacial surgery}, doi = {10.1016/j.ijom.2013.09.003}, volume = {43}, number = {4}, issn = {0901-5027}, title = {Comparative study between lag screw and miniplate fixation for straight midline mandibular osteotomy.}, keyword = {lag screw, mandible fixation, mandible osteosynthesis, mandibulotomy, miniplate} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font