Pregled bibliografske jedinice broj: 719794
A current limiting technique for V/f controlled induction machines
A current limiting technique for V/f controlled induction machines // Proceedings of the 16th International Power Electronics and Motion Control Conference and Exposition, PEMC 2014
Antalya, Turska, 2014. str. 1001-1004 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 719794 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
A current limiting technique for V/f controlled induction machines
Autori
Kutija, Martina ; Sumina, Damir ; Čolović, Igor
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 16th International Power Electronics and Motion Control Conference and Exposition, PEMC 2014
/ - , 2014, 1001-1004
Skup
16th International Power Electronics and Motion Control Conference and Exposition, PEMC
Mjesto i datum
Antalya, Turska, 21.09.2014. - 24.09.2014
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
constant V/f control method; current limiting technique; induction machine
Sažetak
This paper describes a current limiting technique for V/f controlled induction machines. In V/f control method stator current is not directly controlled so the implementation of current limiter is a challenging task. The current limiter proposed in this paper is composed of a programmable ramp and two proportional-integral (PI) controllers which keep the stator current below the limit. The programmable ramp provides limiting of the stator current during the induction machine acceleration and deceleration whereas the PI controllers, if necessary, ensure a further decrease of the stator current during the transients. Moreover, the PI controllers also keep the stator current under the limit during the steady state. The proposed method is implemented in digital control system and verified on the laboratory model. Experimental setup consists of a squirrel-cage induction machine (560 kW) connected to the grid via back-to-back converter and permanent magnet machine (375 kW) connected to the grid via industrial frequency converter. Experimental results show the satisfactory performance of the proposed current limiting technique.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
036-0361621-1626 - Upravljanje sinkronim agregatom s obzirom na zahtjeve elektroenergetskog sustava (Erceg, Gorislav, MZO ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb