Diagnostic efficiency of bioimpedance measurements
Diagnostic efficiency of bioimpedance measurements // Proceedings of the International Federation for Medical & Biological Engineering Medicon 2001 / Magjarević, R; Tonković, S.; Bilas, V.; Lacković, I. (ur.).
Zagreb: Hrvatsko društvo za biomedicinsko inženjerstvo i medicinsku fiziku ; Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2001. str. 66-69 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 71607 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Diagnostic efficiency of bioimpedance measurements
Autori
Tonković, Stanko
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the International Federation for Medical & Biological Engineering Medicon 2001
/ Magjarević, R; Tonković, S.; Bilas, V.; Lacković, I. - Zagreb : Hrvatsko društvo za biomedicinsko inženjerstvo i medicinsku fiziku ; Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2001, 66-69
Skup
IX Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2001
Mjesto i datum
Pula, Hrvatska, 12.06.2001. - 15.06.2001
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Sažetak
More than one century ago started the interest of researchers for bioimpedance measurements, "in vitro" or "in vivo". In this short overview, we shall consider only "in vivo" applications by use of surface self-adhesive electrodes. Today, bioimpedance measurements reveal an important interest as one method for noninvasive exploration of tissue structure and properties or physiologic events, i.e. "static" or "dynamic" human organism properties. In addition to noninvasivity, measurements and required instrumentation is simple, not expensive and imposes not the demands for highly skilled staff. One of the main problems, when bioimpedance measurements are considered, is the reliability of results. This means problem of elimination the effect of electrode impedance, the repeatability of measurements and establishing the criterion of normality for particular measurement procedures. This paper presents also the results of the research performed on patients with ischemic syndromes in lower legs.