Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 71562

Accuracy improvement of noninvasive finger blood pressure measurement


Lacković, Igor; Šantić, Ante
Accuracy improvement of noninvasive finger blood pressure measurement // Proceedings of the International Federation for Medical & Biological Engineering, vol. 1, Medicon 2001 / Magjarević, R. ; Tonković, S. ; Bilas, V. ; Lacković, I. (ur.).
Zagreb: Hrvatsko društvo za biomedicinsko inženjerstvo i medicinsku fiziku ; Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2001. str. 281-284 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 71562 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Accuracy improvement of noninvasive finger blood pressure measurement

Autori
Lacković, Igor ; Šantić, Ante

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the International Federation for Medical & Biological Engineering, vol. 1, Medicon 2001 / Magjarević, R. ; Tonković, S. ; Bilas, V. ; Lacković, I. - Zagreb : Hrvatsko društvo za biomedicinsko inženjerstvo i medicinsku fiziku ; Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2001, 281-284

Skup
IX Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2001

Mjesto i datum
Pula, Hrvatska, 12.06.2001. - 15.06.2001

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Sažetak
For blood pressure measurement in finger a combined measurement method was developed. The method is based on the usage of an air-filled finger cuff for occlusion of proximal finger arteries and a pulse sensor placed at the fingertip for detecting distal arterial volume changes. Improved algorithms for systolic and diastolic pressure determination are described. Systolic pressure determination is based on detection of appearance of distal oscillations, along with the simultaneous determination with the algorithm based on the envelope of proximal oscillations. Diastolic pressure determination is based on calculation of weighted average of pressures obtained by three algorithms - from the envelope of difference of proximal and distal oscillations, from the envelope of proximal oscillations and from the transit time curve. Experimental evaluation was performed on 32 subjects. The accuracy improvement of both systolic and diastolic pressure measurement was achieved.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
036026

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Igor Lacković (autor)

Avatar Url Ante Šantić (autor)


Citiraj ovu publikaciju:

Lacković, Igor; Šantić, Ante
Accuracy improvement of noninvasive finger blood pressure measurement // Proceedings of the International Federation for Medical & Biological Engineering, vol. 1, Medicon 2001 / Magjarević, R. ; Tonković, S. ; Bilas, V. ; Lacković, I. (ur.).
Zagreb: Hrvatsko društvo za biomedicinsko inženjerstvo i medicinsku fiziku ; Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2001. str. 281-284 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Lacković, I. & Šantić, A. (2001) Accuracy improvement of noninvasive finger blood pressure measurement. U: Magjarević, R., Tonković, S., Bilas, V. & Lacković, I. (ur.)Proceedings of the International Federation for Medical & Biological Engineering, vol. 1, Medicon 2001.
@article{article, author = {Lackovi\'{c}, Igor and \v{S}anti\'{c}, Ante}, year = {2001}, pages = {281-284}, keywords = {}, title = {Accuracy improvement of noninvasive finger blood pressure measurement}, keyword = {}, publisher = {Hrvatsko dru\v{s}tvo za biomedicinsko in\v{z}enjerstvo i medicinsku fiziku ; Fakultet elektrotehnike i ra\v{c}unarstva Sveu\v{c}ili\v{s}ta u Zagrebu}, publisherplace = {Pula, Hrvatska} }
@article{article, author = {Lackovi\'{c}, Igor and \v{S}anti\'{c}, Ante}, year = {2001}, pages = {281-284}, keywords = {}, title = {Accuracy improvement of noninvasive finger blood pressure measurement}, keyword = {}, publisher = {Hrvatsko dru\v{s}tvo za biomedicinsko in\v{z}enjerstvo i medicinsku fiziku ; Fakultet elektrotehnike i ra\v{c}unarstva Sveu\v{c}ili\v{s}ta u Zagrebu}, publisherplace = {Pula, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font