Pregled bibliografske jedinice broj: 714087
Load Management Scheme Using Air Conditioning Electric Power Consumption and Photovoltaic Power System Generation
Load Management Scheme Using Air Conditioning Electric Power Consumption and Photovoltaic Power System Generation // Journal of energy and power engineering, 8 (2014), 11; 1926-1932 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 714087 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Load Management Scheme Using Air Conditioning Electric Power Consumption and Photovoltaic Power System Generation
Autori
Klaić, Zvonimir ; Šljivac, Damir ; Fekete, Krešimir ; Kraus, Zorislav
Izvornik
Journal of energy and power engineering (1934-8975) 8
(2014), 11;
1926-1932
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Photovoltaic Power Plant ; Smart Grid ; Load Management ; Air Conditioning System ; Power Measurements
Sažetak
In the last few decades, in the world and also in the European Union, considerable resources have been invested in the rapid development of renewable energy sources and distributed generation in general. At the same time, power consumption is continuously increasing, and consumers are becoming more complex, which ultimately requires new investments in the distribution network. Concept of Smart Grids is generally accepted as a possible solution. Smart grid is a concept with many elements, where monitoring and control of every element in the chain of production, transmission, distribution and final consumption enables much more efficient delivery and use of electricity. One of the elements of smart grid efficiency is the ability of real-time demand-supply balancing. This balancing is carried out by monitoring of consumption and redistribution of electricity among individual end users, according to their needs. The aim of this paper is creating algorithm for real-time load management using power measurements. Algorithm for real-time load management at the Faculty of Electrical Engineering in Osijek (ETFOS), Croatia is created based on measurements of photovoltaic power plant production, the power consumption of air conditioning system and the faculty building total electricity consumption. Expected result of real-time re-dispatching of air conditioners consumption, depending on the level of electricity production in photovoltaic power plant is decreasing peak demand of the faculty.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike, računarstva i informacijskih tehnologija Osijek
Profili:
Krešimir Fekete
(autor)
Zvonimir Klaić
(autor)
Zorislav Kraus
(autor)
Damir Šljivac
(autor)
Citiraj ovu publikaciju:
Uključenost u ostale bibliografske baze podataka::
- CA Search (Chemical Abstracts)
- AcademicKeys
- CiteFactor
- CNKI
- CSA
- EBSCO
- Electronic Journals Library
- getCITED
- Google Scholar
- INNO SPACE
- Newjour
- OCLC
- Periodicals Directory
- ProQuest
- RoMEO
- SJournals
- Summon Serials Solutions
- Ulrich's International