Pregled bibliografske jedinice broj: 709125
Accuracy and reliability of pulp/tooth area ratio in upper canines by peri-apical X-rays
Accuracy and reliability of pulp/tooth area ratio in upper canines by peri-apical X-rays // Legal Medicine, 16 (2014), 6; 337-343 doi:10.1016/j.legalmed.2014.07.002 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 709125 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Accuracy and reliability of pulp/tooth area ratio in upper canines by peri-apical X-rays
Autori
Azevedo, A.C. ; Michel-Crosato, E. ; Biazevic, M.G.H. ; Galić, Ivan ; Merelli, V. , De Luca, S. ; Cameriere, R.
Izvornik
Legal Medicine (1344-6223) 16
(2014), 6;
337-343
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
human identification; age estimation; pulp/tooth area; upper canines; reliability; Italy
(human identification; age estimation; pulp/tooth area; uUpper canines; reliability; Italy)
Sažetak
Due to the real need for careful staff training in age assessment, in order to improve capacity, consistency and competence, new research on the reliability and repeatability of methods frequently used in age assessment are required. The aim of this study was twofold: first, to test the accuracy of this method for age estimation ; second, to obtain data on the reliability of this technique. A sample of 81 peri-apical radiographs of upper canines (44 men and 37 women), aged between 19 and 74years, was used ; the teeth were taken from the osteological collection of Sassari (Sardinia, Italy). Three blinded observers used the technique in order to perform the age estimation. The mean real age of the 81 observations was 37.21 (CI95% 34.37 40.05), and estimated ages ranged from 36.65 to 38.99 (CI95%- Ex1 35.42 ; 41.28 ; CI95%-Ex2 33.89 ; 39.41 ; CI95%- Ex3 35.92 ; 42.06). The module differences found by the three observers were 3.43, 4.24 and 4.45, respectively for Ex1×Ex2, Ex1×Ex3 and Ex2×Ex3. The module differences observed among real and observed ages were 2.55 (CI95% 1.90 ; 3.20), 2.22 (CI95% 1.65 ; 2.78) and 4.39 (CI95% 3.80 ; 5.75), respectively for Ex1, Ex2 and Ex3. No differences were observed among measurements. This technique can be reproduced and repeated after proper training, since it was found high reliability and accuracy.
Izvorni jezik
Engleski
Znanstvena područja
Biologija, Dentalna medicina, Pravo
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE
Uključenost u ostale bibliografske baze podataka::
- BIOSIS Previews (Biological Abstracts)
- MEDLINE