Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 705363

Comparison of ventilation threshold and heart rate deflection point in fast and standard treadmill test protocols


Vučetić, Vlatko; Šentija, Davor; Sporiš, Goran; Trajković, Nebojša; Milanović, Zoran
Comparison of ventilation threshold and heart rate deflection point in fast and standard treadmill test protocols // Acta clinica Croatica, 53 (2014), 2; 190-203 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 705363 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparison of ventilation threshold and heart rate deflection point in fast and standard treadmill test protocols

Autori
Vučetić, Vlatko ; Šentija, Davor ; Sporiš, Goran ; Trajković, Nebojša ; Milanović, Zoran

Izvornik
Acta clinica Croatica (0353-9466) 53 (2014), 2; 190-203

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Exercise test ; Anaerobic threshold ; Treadmill test ; Heart rate ; Pulmonary ventilation Correspondence

Sažetak
The purpose of this study was to compare two methods for determination of anaerobic threshold from two different treadmill protocols. Forty- eight Croatian runners of national rank (ten sprinters, fifteen 400-m runners, ten middle distance runners and thirteen long distance runners), mean age 21.7±5.1 years, participated in the study. They performed two graded maximal exercise tests on a treadmill, a standard ramp treadmill test (TSR, speed increments of 1 km•h-1 every 60 seconds) and a fast ramp treadmill test (TFR, speed increments of 1 km•h-1 every 30 seconds) to determine and compare the parameters at peak values and at heart rate at the deflection point (HR DP) and ventilation threshold (VT ). There were no significant differences between protocols (p>0.05) for peak values of oxygen uptake (VO2max, 4.48±0.43 and 4.44±0.45 L•min- 1), weight related VO2max (62.5±6.2 and 62.0±6.0 mL•kg-1•min-1), pulmonary ventilation (VE max, 163.1±18.7 and 161.3±19.9 L•min-1) and heart rate (HR max, 192.3±8.5 and 194.4±8.7 bpm) (TFR and TSR, respectively). Moreover, no significant differences between TFR and TSR where found for VT and HR DP when expressed as VO2 and HR . However, there was a significant effect of ramp slope on running speed at VO2max and at the anaerobic threshold (AnT) , independent of the method used (VT : 16.0±2.2 vs 14.9±2.2 km•h-1 ; HR DP: 16.5±1.9 vs 14.9±2.0 km•h-1 for TFR and TSR respectively). Linear regression analysis revealed high between-test and between-method correlations for VO2, HR and running speed parameters (r=0.78- 0.89, p<0.01). The present study has indicated that the VT and HR DP for running (VO2, ventilation, and heart rate at VT /HR DP) are independent of test protocol, while there is a significant effect of ramp slope on VT and HR DP when expressed as running speed. Moreover, this study demonstrates that the point of deflection from linearity of heart rate may be an accurate

Izvorni jezik
Engleski

Znanstvena područja
Kineziologija



POVEZANOST RADA


Ustanove:
Kineziološki fakultet, Zagreb

Profili:

Avatar Url Davor Šentija (autor)

Avatar Url Goran Sporiš (autor)

Avatar Url Vlatko Vučetić (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada Hrčak

Citiraj ovu publikaciju:

Vučetić, Vlatko; Šentija, Davor; Sporiš, Goran; Trajković, Nebojša; Milanović, Zoran
Comparison of ventilation threshold and heart rate deflection point in fast and standard treadmill test protocols // Acta clinica Croatica, 53 (2014), 2; 190-203 (međunarodna recenzija, članak, znanstveni)
Vučetić, V., Šentija, D., Sporiš, G., Trajković, N. & Milanović, Z. (2014) Comparison of ventilation threshold and heart rate deflection point in fast and standard treadmill test protocols. Acta clinica Croatica, 53 (2), 190-203.
@article{article, author = {Vu\v{c}eti\'{c}, Vlatko and \v{S}entija, Davor and Spori\v{s}, Goran and Trajkovi\'{c}, Neboj\v{s}a and Milanovi\'{c}, Zoran}, year = {2014}, pages = {190-203}, keywords = {Exercise test, Anaerobic threshold, Treadmill test, Heart rate, Pulmonary ventilation Correspondence}, journal = {Acta clinica Croatica}, volume = {53}, number = {2}, issn = {0353-9466}, title = {Comparison of ventilation threshold and heart rate deflection point in fast and standard treadmill test protocols}, keyword = {Exercise test, Anaerobic threshold, Treadmill test, Heart rate, Pulmonary ventilation Correspondence} }
@article{article, author = {Vu\v{c}eti\'{c}, Vlatko and \v{S}entija, Davor and Spori\v{s}, Goran and Trajkovi\'{c}, Neboj\v{s}a and Milanovi\'{c}, Zoran}, year = {2014}, pages = {190-203}, keywords = {Exercise test, Anaerobic threshold, Treadmill test, Heart rate, Pulmonary ventilation Correspondence}, journal = {Acta clinica Croatica}, volume = {53}, number = {2}, issn = {0353-9466}, title = {Comparison of ventilation threshold and heart rate deflection point in fast and standard treadmill test protocols}, keyword = {Exercise test, Anaerobic threshold, Treadmill test, Heart rate, Pulmonary ventilation Correspondence} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font