Pregled bibliografske jedinice broj: 70161
Topically Applied Migrating Corrosion Inhibitors for Reinforced Concrete Protection
Topically Applied Migrating Corrosion Inhibitors for Reinforced Concrete Protection // Proceedings of Eurocorr 2000 Past Successes - Future Challenges / Don Harrop (ur.).
London : Delhi: IoM Communication Ltd, 2000. str. 204-209 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 70161 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Topically Applied Migrating Corrosion Inhibitors for Reinforced Concrete Protection
Autori
Bjegović, Dubravka ; Mikšić, Boris
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of Eurocorr 2000 Past Successes - Future Challenges
/ Don Harrop - London : Delhi : IoM Communication Ltd, 2000, 204-209
Skup
Proceedings of Eurocorr 2000 Past Successes - Future Challenges
Mjesto i datum
London, Ujedinjeno Kraljevstvo, 10.09.2000. - 14.09.2000
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
corrosion; reinforcement; corrosion inhibitor; protection
Sažetak
Several types of corrosion protection systems for reinforced concrete are available and used today. The most recent technology is the application of migrating corrosion inhibitors (MCIâ), which decrease the corrosion rate of the reinforcement embedded in concrete. Migrating corrosion inhibitors are a mixed (anodic /cathodic) amino-carboxylate based inhibitor system. A migrating corrosion inhibitor topical treatment, will migrate to the reinforcement first by capillary suction and than by diffusion (both liquid and vapour) at Bjegović et al [1].
In this paper the inhibition mechanism of the migrating corrosion inhibitors is explained. Concrete beams were made as substrate specimens. After 28 days the upper surface of the specimens was cleaned by steel brush and three types of topical protection systems were applied, Table 1. After the application of the protection systems the specimens were cured for two weeks at 20°C and 65% RH
and than testing per ASTM G 109. This procedure was repeated in the course of one year.
Izvorni jezik