Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 700404

Preliminary radiation doses assessment for NPP Krško SBO sequence


Konjarek, Damir; Bajs, Tomislav; Šinka, Davor
Preliminary radiation doses assessment for NPP Krško SBO sequence // Proceedings of the 10th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids / Čavlina, Nikola ; Grgić, Davor ; Pevec, Dubravko (ur.).
Zagreb: Hrvatsko nuklearno društvo, 2014. str. 170-1 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 700404 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Preliminary radiation doses assessment for NPP Krško SBO sequence

Autori
Konjarek, Damir ; Bajs, Tomislav ; Šinka, Davor

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the 10th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids / Čavlina, Nikola ; Grgić, Davor ; Pevec, Dubravko - Zagreb : Hrvatsko nuklearno društvo, 2014, 170-1

ISBN
978-953-55224-6-1

Skup
10th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids

Mjesto i datum
Zadar, Hrvatska, 01.06.2014. - 04.06.2014

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
radiation doses; INTERRAS; Krško NPP; SBO; release rates; iodine; LERF; filtered venting

Sažetak
Accidents at nuclear power plants may require urgent measures to prevent deterministic effects and reduce stochastic consequences. The need for fast decision making is restricted with great uncertainty of what is known about the situation in the early phase of an accident. In particular, magnitude, beginning and duration of a release are subject to considerable uncertainty and meteorological information might be unavailable or vague. This calls for simplistic and robust decision criteria which is defined in emergency preparedness zones. Recent developments on international level, especially after Fukushima accident emphasized need to have harmonized emergency preparedness zones in case of close proximity of nuclear power plants to the national borders. Example of such a case is Nuclear Power Plant Krško (NEK) that is located just 10 km from Croatian- Slovenian border. Emergency zones in Croatia and Slovenia do not have adequate level of harmonization. Croatian State Office for Radiological and Nuclear Safety (DZRNS – Državni zavod za radiološku i nuklearnu sigurnost) initiated an activity to gather background information based on which harmonization of emergency preparedness planning zones could be done between Croatia and Slovenia. In order to achieve this, use of NEK PSA (Probabilistic Safety Assessment) Level II, LERF (Large, early release frequency) and Release Frequency (RF) results has been explored. Additionally, impact of recent modification PCFVS (Passive Containment Filtered Vent System) has been investigated. Release category corresponding to the SBO (Station BlackOut) was selected to investigate the influence of PCFVS modification that enables controlled and filtered release of containment structure. IAEA available code INTERRAS (INTERnational Radiological Assessment System) module ST-Dose (Source Term to Dose) was used to estimate projected radiation doses from a radioactive plume to the environment. With this module it is possible to make preliminary assessment of consequences to the environment in case of adverse reactor conditions or releases from radioactive materials. Its intended usage is for quick assessment of consequences of radiological release before and during initial phases of nuclear accident when radiological measurements is still not possible or is limited. This paper represent preliminary finding as the conservative boundary conditions in calculation yield doses close to intervention levels.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
036-0361590-1589 - Nuklearne elektrane za održivu proizvodnju električne energije (Feretić, Danilo, MZO ) ( CroRIS)

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Davor Šinka (autor)

Avatar Url Tomislav Bajs (autor)


Citiraj ovu publikaciju:

Konjarek, Damir; Bajs, Tomislav; Šinka, Davor
Preliminary radiation doses assessment for NPP Krško SBO sequence // Proceedings of the 10th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids / Čavlina, Nikola ; Grgić, Davor ; Pevec, Dubravko (ur.).
Zagreb: Hrvatsko nuklearno društvo, 2014. str. 170-1 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Konjarek, D., Bajs, T. & Šinka, D. (2014) Preliminary radiation doses assessment for NPP Krško SBO sequence. U: Čavlina, N., Grgić, D. & Pevec, D. (ur.)Proceedings of the 10th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids.
@article{article, author = {Konjarek, Damir and Bajs, Tomislav and \v{S}inka, Davor}, year = {2014}, pages = {170-1-170-18}, keywords = {radiation doses, INTERRAS, Kr\v{s}ko NPP, SBO, release rates, iodine, LERF, filtered venting}, isbn = {978-953-55224-6-1}, title = {Preliminary radiation doses assessment for NPP Kr\v{s}ko SBO sequence}, keyword = {radiation doses, INTERRAS, Kr\v{s}ko NPP, SBO, release rates, iodine, LERF, filtered venting}, publisher = {Hrvatsko nuklearno dru\v{s}tvo}, publisherplace = {Zadar, Hrvatska} }
@article{article, author = {Konjarek, Damir and Bajs, Tomislav and \v{S}inka, Davor}, year = {2014}, pages = {170-1-170-18}, keywords = {radiation doses, INTERRAS, Kr\v{s}ko NPP, SBO, release rates, iodine, LERF, filtered venting}, isbn = {978-953-55224-6-1}, title = {Preliminary radiation doses assessment for NPP Kr\v{s}ko SBO sequence}, keyword = {radiation doses, INTERRAS, Kr\v{s}ko NPP, SBO, release rates, iodine, LERF, filtered venting}, publisher = {Hrvatsko nuklearno dru\v{s}tvo}, publisherplace = {Zadar, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font