Pregled bibliografske jedinice broj: 697972
Constant cardiac output monitoring using the PiCCO and LiDCO methods versus PAK in septic patients: when to do calibration?
Constant cardiac output monitoring using the PiCCO and LiDCO methods versus PAK in septic patients: when to do calibration? // Acta clinica Croatica, 50 (2011), 2; 267-272 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 697972 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Constant cardiac output monitoring using the PiCCO and LiDCO methods versus PAK in septic patients: when to do calibration?
Autori
Širanović, Mladen ; Kovač, Joško ; Gopčević, Aleksandar ; Kelečić, Mijo ; Vučić, Marinko ; Kovač, Nataša ; Rode, Bojan B
Izvornik
Acta clinica Croatica (0353-9466) 50
(2011), 2;
267-272
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Cardiac output ; Monitoring ; Sepsis ; Intensive care
Sažetak
The accuracy of cardiac output measurement by two most widely used methods of less invasive hemodynamic monitoring and by the standard technique of thermodilution with pulmonary catheter was assessed. The measurements were carried out in septic surgical patients immediately after and between system calibrations. Study results showed satisfactory compatibility of measurements performed by the two methods and by pulmonary catheter in both phases, thus system calibration being recommendable in hemodynamically unstable septic patients.