Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 696227

Design, Development and Testing of a Low-Cost sEMG System and Its Use in Recording Muscle Activity in Human Gait


Grujić Tamara; Kuzmanić Skelin, Ana; Čić, Maja
Design, Development and Testing of a Low-Cost sEMG System and Its Use in Recording Muscle Activity in Human Gait // Sensors, 14 (2014), 5; 8235-8258 doi:10.3390/s140508235 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 696227 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Design, Development and Testing of a Low-Cost sEMG System and Its Use in Recording Muscle Activity in Human Gait

Autori
Grujić Tamara ; Kuzmanić Skelin, Ana ; Čić, Maja

Izvornik
Sensors (1424-8220) 14 (2014), 5; 8235-8258

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
surface electromyography (sEMG) signals; biomedical sensors; bioamplifier; artificial EMG signal; noise removal; wavelets; EMG signal envelope; muscle activity during human gait

Sažetak
Surface electromyography (sEMG) is an important measurement technique used in biomechanical, rehabilitation and sport environments. In this article the design, development and testing of a low-cost wearable sEMG system are described. The hardware architecture consists of a two-cascade small-sized bioamplifier with a total gain of 2, 000 and band-pass of 3 to 500 Hz. The sampling frequency of the system is 1, 000 Hz. Since real measured EMG signals are usually corrupted by various types of noises (motion artifacts, white noise and electromagnetic noise present at 50 Hz and higher harmonics), we have tested several denoising techniques, both on artificial and measured EMG signals. Results showed that a wavelet—based technique implementing Daubechies5 wavelet and soft sqtwolog thresholding is the most appropriate for EMG signals denoising. To test the system performance, EMG activities of six dominant muscles of ten healthy subjects during gait were measured (gluteus maximus, biceps femoris, sartorius, rectus femoris, tibialis anterior and medial gastrocnemius). The obtained EMG envelopes presented against the duration of gait cycle were compared favourably with the EMG data available in the literature, suggesting that the proposed system is suitable for a wide range of applications in biomechanics.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split

Profili:

Avatar Url Maja Čić (autor)

Avatar Url Ana Kuzmanić Skelin (autor)

Avatar Url Tamara Grujić (autor)

Poveznice na cjeloviti tekst rada:

doi

Citiraj ovu publikaciju:

Grujić Tamara; Kuzmanić Skelin, Ana; Čić, Maja
Design, Development and Testing of a Low-Cost sEMG System and Its Use in Recording Muscle Activity in Human Gait // Sensors, 14 (2014), 5; 8235-8258 doi:10.3390/s140508235 (međunarodna recenzija, članak, znanstveni)
Grujić Tamara, Kuzmanić Skelin, A. & Čić, M. (2014) Design, Development and Testing of a Low-Cost sEMG System and Its Use in Recording Muscle Activity in Human Gait. Sensors, 14 (5), 8235-8258 doi:10.3390/s140508235.
@article{article, author = {Kuzmani\'{c} Skelin, Ana and \v{C}i\'{c}, Maja}, year = {2014}, pages = {8235-8258}, DOI = {10.3390/s140508235}, keywords = {surface electromyography (sEMG) signals, biomedical sensors, bioamplifier, artificial EMG signal, noise removal, wavelets, EMG signal envelope, muscle activity during human gait}, journal = {Sensors}, doi = {10.3390/s140508235}, volume = {14}, number = {5}, issn = {1424-8220}, title = {Design, Development and Testing of a Low-Cost sEMG System and Its Use in Recording Muscle Activity in Human Gait}, keyword = {surface electromyography (sEMG) signals, biomedical sensors, bioamplifier, artificial EMG signal, noise removal, wavelets, EMG signal envelope, muscle activity during human gait} }
@article{article, author = {Kuzmani\'{c} Skelin, Ana and \v{C}i\'{c}, Maja}, year = {2014}, pages = {8235-8258}, DOI = {10.3390/s140508235}, keywords = {surface electromyography (sEMG) signals, biomedical sensors, bioamplifier, artificial EMG signal, noise removal, wavelets, EMG signal envelope, muscle activity during human gait}, journal = {Sensors}, doi = {10.3390/s140508235}, volume = {14}, number = {5}, issn = {1424-8220}, title = {Design, Development and Testing of a Low-Cost sEMG System and Its Use in Recording Muscle Activity in Human Gait}, keyword = {surface electromyography (sEMG) signals, biomedical sensors, bioamplifier, artificial EMG signal, noise removal, wavelets, EMG signal envelope, muscle activity during human gait} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka::


  • INSPEC
  • MEDLINE
  • Analytical Abstracts
  • CAB Abstracts
  • INSPEC
  • MEDLINE
  • SCI Expanded (Web of science)
  • Chemical Abstracts (CAS)
  • Chemistry Citation Index
  • Directory of Open Access Journals (DOAJ)
  • e-Helvetica (Swiss National Library Archive)
  • EBSCOhost
  • IndexCopernicus
  • Open-J-Gate
  • SCOPUS/SciVerse
  • Google sholar
  • Journal Citation Report
  • PubMed Central
  • Scirus
  • SciSearch


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font