The Feasibility Analysis of Replacing the Standard Ammonia Refrigeration Device with the Cascade NH3/CO2 Refrigeration Device in Food Industry


Jankovich, Dennis; Osman, Krešimir
The Feasibility Analysis of Replacing the Standard Ammonia Refrigeration Device with the Cascade NH3/CO2 Refrigeration Device in Food Industry // Thermal science, 19 (2015), 5; 1821-1833 doi:10.2298/TSCI130611097J (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 689163 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The Feasibility Analysis of Replacing the Standard Ammonia Refrigeration Device with the Cascade NH3/CO2 Refrigeration Device in Food Industry

Autori
Jankovich, Dennis ; Osman, Krešimir

Izvornik
Thermal science (0354-9836) 19 (2015), 5; 1821-1833

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
natural refrigerants; ammonia; carbon dioxide; ammonia refrigeration device; cascade NH3/CO2 refrigeration device; total refrigeration factor ɛ; total refrigeration load Q0; LC; total reactive power P; heat exchanger mean temperature Tm; condensing temperature of the low temperature part Tc; LC

Sažetak
The thermodynamic analysis shows the feasibility of replacing the standard ammonia refrigeration device with the cascade NH3/CO2 refrigeration device in food industry. The main reason for replacing is to reduce the total amount of ammonia in spaces like deep-freezing chambers, daily chambers, working rooms and technical passageways. An ammonia-contaminated area is hazardous to human health and the safety of food products. This is why the preferred reduced amount of ammonia is accumulated in the Central Refrigeration Engine Room, where the cascade NH3/CO2 device is installed as well. Furthermore, the analysis discusses and compares two left Carnots refrigeration cycles, one for the standard ammonia device and the other for the cascade NH3/CO2 device. Both cycles are processes with two-stage compression and two-stage throttling. The thermodynamic analysis demonstrates that the selected refrigeration cycle is the most cost- effective process because it provides the best numerical values for total refrigeration factor for the observed refrigeration cycle ɛ. The main analyzed influential parameters of the cascade device are: total refrigeration load Q0, LC, total reactive power P, heat exchanger mean temperature Tm and condensing temperature of the low temperature part Tc, LC .

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Projekti:
120-1201829-1828 - Modeli i metode upravljanja znanjem u razvoju proizvoda (Marjanović, Dorian, MZOS ) ( CroRIS)

Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb

Profili:

Avatar Url Dennis Jankovich (autor)

Avatar Url Krešimir Osman (autor)

Poveznice na cjeloviti tekst rada:

doi thermalscience.vinca.rs

Citiraj ovu publikaciju:

Jankovich, Dennis; Osman, Krešimir
The Feasibility Analysis of Replacing the Standard Ammonia Refrigeration Device with the Cascade NH3/CO2 Refrigeration Device in Food Industry // Thermal science, 19 (2015), 5; 1821-1833 doi:10.2298/TSCI130611097J (međunarodna recenzija, članak, znanstveni)
Jankovich, D. & Osman, K. (2015) The Feasibility Analysis of Replacing the Standard Ammonia Refrigeration Device with the Cascade NH3/CO2 Refrigeration Device in Food Industry. Thermal science, 19 (5), 1821-1833 doi:10.2298/TSCI130611097J.
@article{article, author = {Jankovich, Dennis and Osman, Kre\v{s}imir}, year = {2015}, pages = {1821-1833}, DOI = {10.2298/TSCI130611097J}, keywords = {natural refrigerants, ammonia, carbon dioxide, ammonia refrigeration device, cascade NH3/CO2 refrigeration device, total refrigeration factor ɛ, total refrigeration load Q0, LC, total reactive power P, heat exchanger mean temperature Tm, condensing temperature of the low temperature part Tc, LC}, journal = {Thermal science}, doi = {10.2298/TSCI130611097J}, volume = {19}, number = {5}, issn = {0354-9836}, title = {The Feasibility Analysis of Replacing the Standard Ammonia Refrigeration Device with the Cascade NH3/CO2 Refrigeration Device in Food Industry}, keyword = {natural refrigerants, ammonia, carbon dioxide, ammonia refrigeration device, cascade NH3/CO2 refrigeration device, total refrigeration factor ɛ, total refrigeration load Q0, LC, total reactive power P, heat exchanger mean temperature Tm, condensing temperature of the low temperature part Tc, LC} }
@article{article, author = {Jankovich, Dennis and Osman, Kre\v{s}imir}, year = {2015}, pages = {1821-1833}, DOI = {10.2298/TSCI130611097J}, keywords = {natural refrigerants, ammonia, carbon dioxide, ammonia refrigeration device, cascade NH3/CO2 refrigeration device, total refrigeration factor ɛ, total refrigeration load Q0, LC, total reactive power P, heat exchanger mean temperature Tm, condensing temperature of the low temperature part Tc, LC}, journal = {Thermal science}, doi = {10.2298/TSCI130611097J}, volume = {19}, number = {5}, issn = {0354-9836}, title = {The Feasibility Analysis of Replacing the Standard Ammonia Refrigeration Device with the Cascade NH3/CO2 Refrigeration Device in Food Industry}, keyword = {natural refrigerants, ammonia, carbon dioxide, ammonia refrigeration device, cascade NH3/CO2 refrigeration device, total refrigeration factor ɛ, total refrigeration load Q0, LC, total reactive power P, heat exchanger mean temperature Tm, condensing temperature of the low temperature part Tc, LC} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Uključenost u ostale bibliografske baze podataka::


  • Science Citation Index - Expanded - Thompson Reuters
  • Journal Citation Reports/Science Edition


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font