Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 687372

The diagnostic accuracy of a 1, 2-mm minilaparoscope


Barišić, Dubravko; Strelec, Mihajlo; Van Der Ven, H; Prietl, G
The diagnostic accuracy of a 1, 2-mm minilaparoscope // Gynaecological endoscopy. Supplement, 5 (1996), 5; 283-286 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 687372 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The diagnostic accuracy of a 1, 2-mm minilaparoscope

Autori
Barišić, Dubravko ; Strelec, Mihajlo ; Van Der Ven, H ; Prietl, G

Izvornik
Gynaecological endoscopy. Supplement (1354-5167) 5 (1996), 5; 283-286

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
diagnostic minilaparoscopy; infertility

Sažetak
Objective To evaluate the diagnostic suitability of a fibreoptic minilaparoscope with a diameter of 1.2 mm. Design Laparoscopy was performed under general anaesthesia, first with a 1.2-mm minilaparoscope, and then immediately with a conventional 10-mm laparoscope. The findings obtained by minilaparoscopy were compared with those obtained by conventional laparoscopy. Setting Two university-based hospitals. Subjects These were 20 patients, whose ages ranged from 16 to 40 years, and body weight from 52 to 115kg. Laparoscopy was performed because of infertility (13 patients), chronic pelvic pain (2), suspected ectopic pregnancy (2), sterilization (1) and for laparoscopic surveillance during operative hysteroscopy (2). Results The visualization of pelvic organs with the minilaparoscope was acceptable, although the size of the video image was smaller when compared with that from a 10-mm telescope. Pelvic findings obtained by minilaparoscopy coincided with those on conventional laparoscopy in 17 patients. Small endometriotic implants in the anterior cul-de-sac, as well as white fibrotic endometriotic plaques in the pouch of Douglas, were misinterpreted in three patients. Adhesions, distal tubal occlusions, small fibroids, hydatid cysts, and tubal pregnancies were correctly diagnosed by minilaparoscope. No complications occurred in any of the 20 patients. Conclusions The 1.2-mm fibreoptic telescope, introduced through the Veress needle, may be useful for diagnostic procedures.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Zagreb,
Klinički bolnički centar Zagreb,
Sveučilište u Zagrebu

Profili:

Avatar Url Dubravko Barišić (autor)

Avatar Url Mihajlo Strelec (autor)


Citiraj ovu publikaciju:

Barišić, Dubravko; Strelec, Mihajlo; Van Der Ven, H; Prietl, G
The diagnostic accuracy of a 1, 2-mm minilaparoscope // Gynaecological endoscopy. Supplement, 5 (1996), 5; 283-286 (međunarodna recenzija, članak, znanstveni)
Barišić, D., Strelec, M., Van Der Ven, H. & Prietl, G. (1996) The diagnostic accuracy of a 1, 2-mm minilaparoscope. Gynaecological endoscopy. Supplement, 5 (5), 283-286.
@article{article, author = {Bari\v{s}i\'{c}, Dubravko and Strelec, Mihajlo and Van Der Ven, H and Prietl, G}, year = {1996}, pages = {283-286}, keywords = {diagnostic minilaparoscopy, infertility}, journal = {Gynaecological endoscopy. Supplement}, volume = {5}, number = {5}, issn = {1354-5167}, title = {The diagnostic accuracy of a 1, 2-mm minilaparoscope}, keyword = {diagnostic minilaparoscopy, infertility} }
@article{article, author = {Bari\v{s}i\'{c}, Dubravko and Strelec, Mihajlo and Van Der Ven, H and Prietl, G}, year = {1996}, pages = {283-286}, keywords = {diagnostic minilaparoscopy, infertility}, journal = {Gynaecological endoscopy. Supplement}, volume = {5}, number = {5}, issn = {1354-5167}, title = {The diagnostic accuracy of a 1, 2-mm minilaparoscope}, keyword = {diagnostic minilaparoscopy, infertility} }

Časopis indeksira: