Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 68552

An accurate absolute-scale measurement of bremsstrahlung following absorption of incident X and gamma rays


Pašić, Selim; Ilakovac, Ksenofont
An accurate absolute-scale measurement of bremsstrahlung following absorption of incident X and gamma rays // 8th International Symposium on Radiation Physics, Abstracts / L. Musilek et al. (ur.).
Prag: International Radiation Physics Society, 2000. str. 257 - 257 (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 68552 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
An accurate absolute-scale measurement of bremsstrahlung following absorption of incident X and gamma rays

Autori
Pašić, Selim ; Ilakovac, Ksenofont

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
8th International Symposium on Radiation Physics, Abstracts / L. Musilek et al. - Prag : International Radiation Physics Society, 2000, 257 - 257

Skup
8th International Symposium on Radiation Physics

Mjesto i datum
Prag, Češka Republika, 05.07.2000. - 09.07.2000

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Bremsstrahlung due to photoelectrons; detector-to-detector scattering

Sažetak
(Part of abstract) The spectrum of bremsstrahlung due to photoelectrons ejected by incident photons of energy 59.5 keV was measured. Two germanium detectors and a fast-slow coincidence system were used in the measurements. One detector was used as the scatterer and the other as detector of bremsstrahlung radiation. A detailed analysis was made of the detected events taking inti account various detector-to-detector cross-talk processes. The measurement yielded a clear spectrum of bremsstrahlung radiation which could be determined on absolute scale. A simple theoretical model gives results in a good agreement with the experimental data.

Izvorni jezik
Engleski

Znanstvena područja
Fizika



POVEZANOST RADA


Projekti:
119208

Ustanove:
Prirodoslovno-matematički fakultet, Zagreb

Profili:

Avatar Url Selim Pašić (autor)

Avatar Url Ksenofont Ilakovac (autor)


Citiraj ovu publikaciju:

Pašić, Selim; Ilakovac, Ksenofont
An accurate absolute-scale measurement of bremsstrahlung following absorption of incident X and gamma rays // 8th International Symposium on Radiation Physics, Abstracts / L. Musilek et al. (ur.).
Prag: International Radiation Physics Society, 2000. str. 257 - 257 (poster, međunarodna recenzija, sažetak, znanstveni)
Pašić, S. & Ilakovac, K. (2000) An accurate absolute-scale measurement of bremsstrahlung following absorption of incident X and gamma rays. U: L. Musilek et al. (ur.)8th International Symposium on Radiation Physics, Abstracts.
@article{article, author = {Pa\v{s}i\'{c}, Selim and Ilakovac, Ksenofont}, year = {2000}, pages = {257 - 257}, keywords = {Bremsstrahlung due to photoelectrons, detector-to-detector scattering}, title = {An accurate absolute-scale measurement of bremsstrahlung following absorption of incident X and gamma rays}, keyword = {Bremsstrahlung due to photoelectrons, detector-to-detector scattering}, publisher = {International Radiation Physics Society}, publisherplace = {Prag, \v{C}e\v{s}ka Republika} }
@article{article, author = {Pa\v{s}i\'{c}, Selim and Ilakovac, Ksenofont}, year = {2000}, pages = {257 - 257}, keywords = {Bremsstrahlung due to photoelectrons, detector-to-detector scattering}, title = {An accurate absolute-scale measurement of bremsstrahlung following absorption of incident X and gamma rays}, keyword = {Bremsstrahlung due to photoelectrons, detector-to-detector scattering}, publisher = {International Radiation Physics Society}, publisherplace = {Prag, \v{C}e\v{s}ka Republika} }




Contrast
Increase Font
Decrease Font
Dyslexic Font