Pregled bibliografske jedinice broj: 680204
Shielding effectiveness measurements in resonant enclosure using mode-tuned and mode-stirred method
Shielding effectiveness measurements in resonant enclosure using mode-tuned and mode-stirred method // ICECom 2013, Conference Proceedings / Bonefačić, Davor ; Šipuš, Zvonimir (ur.).
Zagreb: Hrvatsko društvo za komunikacije, računarstvo, elektroniku, mjerenja I automatiku (KoREMA), 2013. str. 1-4 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 680204 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Shielding effectiveness measurements in resonant enclosure using mode-tuned and mode-stirred method
Autori
Senić, Damir ; Šarolić, Antonio
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
ICECom 2013, Conference Proceedings
/ Bonefačić, Davor ; Šipuš, Zvonimir - Zagreb : Hrvatsko društvo za komunikacije, računarstvo, elektroniku, mjerenja I automatiku (KoREMA), 2013, 1-4
ISBN
978-953-6037-65-0
Skup
21st International Conference on Applied Electromagnetics and Communications (ICECom 2013)
Mjesto i datum
Dubrovnik, Hrvatska, 14.10.2013. - 16.10.2013
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
shielding effectiveness; conductive enclosures; GTEM cell; reverberation chamber; mode-tuning; mode-stirring
Sažetak
A comparison in determining the shielding effectiveness of resonant conductive enclosures, having apertures in a removable side wall, using mode-tuned and mode-stirred methods is introduced. The measurement setup was based on GTEM cell as a compact field-generating environment, capable of accommodating small enclosures as DUTs. The signal was fed into the GTEM cell, thus creating a controlled incident field impinging on the enclosure. The field level inside the exposed enclosure was collected as the output signal. Highly expressed resonances were attenuated by introducing the mechanical stirring into the enclosure, thus turning the inside of the enclosure into a reverberation chamber. Additionally, the resonant behavior of the enclosure was reduced by introducing the water containers within the enclosure volume as dissipative load, consequently lowering the enclosure Q factor. The results obtained using mode-tuned and mode-stirred method were in good agreement.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
023-0000000-3273 - Mjerenja u području EMC i istraživanja EM utjecaja na zdravlje (Šarolić, Antonio, MZOS ) ( CroRIS)
036-0361630-1631 - Elektromagnetska kompatibilnost - zaštita okoliša (Modlic, Borivoj, MZO ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split