Pregled bibliografske jedinice broj: 679127
Anionic Surfactants Determination in Industrial Effluents by Sequential Injection Analysis with Potentiometric Detection
Anionic Surfactants Determination in Industrial Effluents by Sequential Injection Analysis with Potentiometric Detection // Second International Symposium on Corrosion and Protection of Materials and Environment
Bar: Crnogorsko društvo za zaštitu materijala i životne sredine, 2012. str. 232-238 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 679127 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Anionic Surfactants Determination in Industrial Effluents by Sequential Injection Analysis with Potentiometric Detection
Autori
Galović, Olivera ; Madunić-Čačić, Dubravka ; Sak-Bosnar, Milan
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Second International Symposium on Corrosion and Protection of Materials and Environment
/ - Bar : Crnogorsko društvo za zaštitu materijala i životne sredine, 2012, 232-238
Skup
Second International Symposium on Corrosion and Protection of Materials and Environment
Mjesto i datum
Bar, Crna Gora, 17.10.2012. - 20.10.2012
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
microfluididcs; sequential injection analysis; anionic surfactant; model; effluent
(microfluidics; sequential injection analysis; anionic surfactant; model; effluent)
Sažetak
Sequential Injection Analysis (SIA) was used in these investigations for determination of anionic surfactants (AS) in diluted detergent formulations, used as model effluents. A flow through home-made potentiometric detector, implemented into a home-made SIA system, recorded the electromotive force changes as a function of the AS concentration investigated. Sodium dodecyl sulfate and sodium dodecyl benzsulfonate were used for the calibration purpose. The specific software was developed for the data aquisition and elaboration, as well as for the instrument control. The detector exhibited almost Nernstian response toward the sufactants investigated down to 10^6 M. A 1, 3-didecyl-2-methylimidazolium-tetraphenylborate ion-pair was applied as electroactive material in the detector sensing element. The standard addition methodology was used for testing the method, whereas the potentiometric titration was used as a reference method.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Ustanove:
Sveučilište u Osijeku - Odjel za kemiju