Pregled bibliografske jedinice broj: 674858
COMPARISON OF HIGH VALUE RESISTANCE STANDARDS USING THE MODIFIED WHEATSTONE BRIDGE AND PICOAMMETER
COMPARISON OF HIGH VALUE RESISTANCE STANDARDS USING THE MODIFIED WHEATSTONE BRIDGE AND PICOAMMETER // Proceedings of XX IMEKO World Congress / Woo, Sam-Yong (ur.).
Busan: International Measurement Confederation (IMEKO), 2012. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 674858 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
COMPARISON OF HIGH VALUE RESISTANCE STANDARDS USING THE MODIFIED WHEATSTONE BRIDGE AND PICOAMMETER
Autori
Leniček, Ivan ; Ilić, Damir ; Ferković, Luka
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of XX IMEKO World Congress
/ Woo, Sam-Yong - Busan : International Measurement Confederation (IMEKO), 2012
Skup
XX IMEKO World Congress
Mjesto i datum
Busan, Republika Koreja, 09.09.2012. - 14.09.2012
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
calibration; high resistance standards; zero-current measurement; modified Wheatstone bridge
Sažetak
In this paper is presented the method for comparison of high value resistance standards by using the modified Wheatstone bridge and picoammeter as current detector, instead of low-impedance current-sensing transimpedance amplifier. Basically, the resistance ratio r can be measured on nominal levels 1:1, 10:1 or 100:1, ensuring the traceability chain from the reference standards of 10 MΩ and 1 GΩ for the range of interest 10 MΩ to 100 GΩ