Comparison of lateral thermal damage of the human peritoneum using monopolar diathermy, Harmonic scalpel and LigaSure
Comparison of lateral thermal damage of the human peritoneum using monopolar diathermy, Harmonic scalpel and LigaSure // Canadian journal of surgery, 55 (2012), 5; 317-321 doi:10.1503/cjs.000711 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 671182 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Comparison of lateral thermal damage of the human peritoneum using monopolar diathermy, Harmonic scalpel and LigaSure
Autori
Družijanić, Nikica ; Pogorelić, Zenon ; Perko, Zdravko ; Mrklić, Ivana ; Tomić, Snježana
Izvornik
Canadian journal of surgery (0008-428X) 55
(2012), 5;
317-321
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
lateral thermal damage; human peritoneum; monopolar diathermy; harmonic scalpel; LigaSure
Sažetak
BACKGROUND: New hemostatic technologies are often employed in open and laparoscopic surgery to reduce duration of surgery and complications. Monopolar diathermy, Harmonic scalpel and LigaSure are routinely used in open and laparoscopic surgery for tissue cutting and hemostasis. We compared lateral thermal damage following in vivo application of 3 commonly used instruments. METHODS: We used monopolar diathermy, Harmonic scalpel and LigaSure to coagulate and divide the peritoneum of patients who underwent median laparotomy. After anesthesia, median supraumbilical laparotomy was performed, and the peritoneum of each patient was coagulated using different devices. Using light microscopy and morphometric imaging analysis, the width of tissue lateral thermal damage was measured from the point of the peritoneal incision. RESULTS: We included 100 patients in our study. After a peritoneal incision, the mean lateral thermal damage of monopolar diathermy, Harmonic scalpel (output power 3), Harmonic scalpel (output power 5) and LigaSure were 215.79 μm, 90.42 μm, 127.48 μm and 144.18 μm, respectively. CONCLUSION: The degree of lateral thermal spread varied by instrument type, power setting and application time. LigaSure and Harmonic scalpel were the safest and most efficient methods of tissue coagulation. Monopolar diathermy resulted in the greatest degree of thermal damage in tissues.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Projekti:
216-0000000-0484 - Dvostruki model ovarijalne kancerogeneze - molekularna i morfološka studija (Tomić, Snježana, MZOS ) ( CroRIS)
Ustanove:
KBC Split,
Medicinski fakultet, Split
Profili:
Nikica Družijanić
(autor)
Snježana Tomić
(autor)
Zdravko Perko
(autor)
Zenon Pogorelić
(autor)
Ivana Mrklić
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE